~ [ source navigation ] ~ [ diff markup ] ~ [ identifier search ] ~

TOMOYO Linux Cross Reference
Linux/Documentation/ABI/testing/sysfs-class-thermal

Version: ~ [ linux-6.12-rc7 ] ~ [ linux-6.11.7 ] ~ [ linux-6.10.14 ] ~ [ linux-6.9.12 ] ~ [ linux-6.8.12 ] ~ [ linux-6.7.12 ] ~ [ linux-6.6.60 ] ~ [ linux-6.5.13 ] ~ [ linux-6.4.16 ] ~ [ linux-6.3.13 ] ~ [ linux-6.2.16 ] ~ [ linux-6.1.116 ] ~ [ linux-6.0.19 ] ~ [ linux-5.19.17 ] ~ [ linux-5.18.19 ] ~ [ linux-5.17.15 ] ~ [ linux-5.16.20 ] ~ [ linux-5.15.171 ] ~ [ linux-5.14.21 ] ~ [ linux-5.13.19 ] ~ [ linux-5.12.19 ] ~ [ linux-5.11.22 ] ~ [ linux-5.10.229 ] ~ [ linux-5.9.16 ] ~ [ linux-5.8.18 ] ~ [ linux-5.7.19 ] ~ [ linux-5.6.19 ] ~ [ linux-5.5.19 ] ~ [ linux-5.4.285 ] ~ [ linux-5.3.18 ] ~ [ linux-5.2.21 ] ~ [ linux-5.1.21 ] ~ [ linux-5.0.21 ] ~ [ linux-4.20.17 ] ~ [ linux-4.19.323 ] ~ [ linux-4.18.20 ] ~ [ linux-4.17.19 ] ~ [ linux-4.16.18 ] ~ [ linux-4.15.18 ] ~ [ linux-4.14.336 ] ~ [ linux-4.13.16 ] ~ [ linux-4.12.14 ] ~ [ linux-4.11.12 ] ~ [ linux-4.10.17 ] ~ [ linux-4.9.337 ] ~ [ linux-4.4.302 ] ~ [ linux-3.10.108 ] ~ [ linux-2.6.32.71 ] ~ [ linux-2.6.0 ] ~ [ linux-2.4.37.11 ] ~ [ unix-v6-master ] ~ [ ccs-tools-1.8.12 ] ~ [ policy-sample ] ~
Architecture: ~ [ i386 ] ~ [ alpha ] ~ [ m68k ] ~ [ mips ] ~ [ ppc ] ~ [ sparc ] ~ [ sparc64 ] ~

Diff markup

Differences between /Documentation/ABI/testing/sysfs-class-thermal (Version linux-6.12-rc7) and /Documentation/ABI/testing/sysfs-class-thermal (Version linux-5.6.19)


  1 What:           /sys/class/thermal/thermal_zon    
  2 Description:                                      
  3                 Strings which represent the th    
  4                 This is given by thermal zone     
  5                 E.g: "acpitz" indicates it's a    
  6                 In order to keep it consistent    
  7                 should be a short, lowercase s    
  8                 dashes.                           
  9                                                   
 10                 RO, Required                      
 11                                                   
 12 What:           /sys/class/thermal/thermal_zon    
 13 Description:                                      
 14                 Current temperature as reporte    
 15                                                   
 16                 Unit: millidegree Celsius         
 17                                                   
 18                 RO, Required                      
 19                                                   
 20 What:           /sys/class/thermal/thermal_zon    
 21 Description:                                      
 22                 One of the predefined values i    
 23                 This file gives information ab    
 24                 currently managing the thermal    
 25                 kernel based algorithm or user    
 26                                                   
 27                 enabled                           
 28                                 enable Kernel     
 29                 disabled                          
 30                                 Preventing ker    
 31                                 trip points so    
 32                                 charge of the     
 33                                                   
 34                 RW, Optional                      
 35                                                   
 36 What:           /sys/class/thermal/thermal_zon    
 37 Description:                                      
 38                 One of the various thermal gov    
 39                                                   
 40                 RW, Required                      
 41                                                   
 42 What:           /sys/class/thermal/thermal_zon    
 43 Description:                                      
 44                 Available thermal governors wh    
 45                 particular zone.                  
 46                                                   
 47                 RO, Required                      
 48                                                   
 49 What:           /sys/class/thermal/thermal_zon    
 50 Description:                                      
 51                 The temperature above which tr    
 52                                                   
 53                 Unit: millidegree Celsius         
 54                                                   
 55                 RO, Optional                      
 56                                                   
 57 What:           /sys/class/thermal/thermal_zon    
 58 Description:                                      
 59                 Strings which indicate the typ    
 60                                                   
 61                 E.g. it can be one of critical    
 62                 for ACPI thermal zone.            
 63                                                   
 64                 RO, Optional                      
 65                                                   
 66 What:           /sys/class/thermal/thermal_zon    
 67 Description:                                      
 68                 The hysteresis value for a tri    
 69                 integer.                          
 70                                                   
 71                 Unit: Celsius                     
 72                                                   
 73                 RW, Optional                      
 74                                                   
 75 What:           /sys/class/thermal/thermal_zon    
 76 Description:                                      
 77         Sysfs link to the thermal cooling devi    
 78         for cooling device throttling control     
 79                                                   
 80         RO, Optional                              
 81                                                   
 82 What:           /sys/class/thermal/thermal_zon    
 83 Description:                                      
 84                 The trip point in this thermal    
 85                 associated with; -1 means the     
 86                 associated with any trip point    
 87                                                   
 88                 RO, Optional                      
 89                                                   
 90 What:           /sys/class/thermal/thermal_zon    
 91 Description:                                      
 92                 The influence of `cdev[0-*]` i    
 93                 is relative to the rest of coo    
 94                 zone. For example, if a coolin    
 95                 than that of other, it's twice    
 96                 thermal zone.                     
 97                                                   
 98                 RW, Optional                      
 99                                                   
100 What:           /sys/class/thermal/thermal_zon    
101 Description:                                      
102                 Interface to set the emulated     
103                 (sensor). After setting this t    
104                 pass this temperature to platf    
105                 registered or cache it locally    
106                 different temperature threshol    
107                 action. This is write only nod    
108                 should disable emulation.         
109                                                   
110                 Unit: millidegree Celsius         
111                                                   
112                 WO, Optional                      
113                                                   
114                 WARNING:                          
115                     Be careful while enabling     
116                     because userland can easil    
117                     flooding this sysfs node w    
118                                                   
119                                                   
120 What:           /sys/class/thermal/thermal_zon    
121 Description:                                      
122                 The derivative term of the pow    
123                 controller. For more informati    
124                 Documentation/driver-api/therm    
125                                                   
126                 RW, Optional                      
127                                                   
128 What:           /sys/class/thermal/thermal_zon    
129 Description:                                      
130                 The integral term of the power    
131                 controller. This term allows t    
132                 for long term drift. For more     
133                 Documentation/driver-api/therm    
134                                                   
135                 RW, Optional                      
136                                                   
137 What:           /sys/class/thermal/thermal_zon    
138 Description:                                      
139                 The proportional term of the p    
140                 controller during temperature     
141                 is when the current temperatur    
142                 temperature" trip point. For m    
143                 Documentation/driver-api/therm    
144                                                   
145                 RW, Optional                      
146                                                   
147 What:           /sys/class/thermal/thermal_zon    
148 Description:                                      
149                 The proportional term of the p    
150                 controller during temperature     
151                 is when the current temperatur    
152                 temperature" trip point. For m    
153                 Documentation/driver-api/therm    
154                                                   
155                 RW, Optional                      
156                                                   
157 What:           /sys/class/thermal/thermal_zon    
158 Description:                                      
159                 Temperature offset from the de    
160                 above which the integral term     
161                 governor's PID controller star    
162                 example, if integral_cutoff is    
163                 accumulates error when tempera    
164                 temperature trip point. For mo    
165                 Documentation/driver-api/therm    
166                                                   
167                 Unit: millidegree Celsius         
168                                                   
169                 RW, Optional                      
170                                                   
171 What:           /sys/class/thermal/thermal_zon    
172 Description:                                      
173                 The slope constant used in a l    
174                 to determine a hotspot tempera    
175                 raw readings. It is up to the     
176                 the usage of these values.        
177                                                   
178                 RW, Optional                      
179                                                   
180 What:           /sys/class/thermal/thermal_zon    
181 Description:                                      
182                 The offset constant used in a     
183                 to determine a hotspot tempera    
184                 raw readings. It is up to the     
185                 the usage of these values.        
186                                                   
187                 RW, Optional                      
188                                                   
189 What:           /sys/class/thermal/thermal_zon    
190 Description:                                      
191                 An estimate of the sustained p    
192                 the thermal zone. Used by the     
193                 more information see              
194                 Documentation/driver-api/therm    
195                                                   
196                 Unit: milliwatts                  
197                                                   
198                 RW, Optional                      
199                                                   
200 What:           /sys/class/thermal/cooling_dev    
201 Description:                                      
202                 String which represents the ty    
203                                                   
204                 - for generic ACPI: should be     
205                 - for memory controller device    
206                   should be "Memory controller    
207                                                   
208                 RO, Required                      
209                                                   
210 What:           /sys/class/thermal/cooling_dev    
211 Description:                                      
212                 The maximum permissible coolin    
213                                                   
214                 RO, Required                      
215                                                   
216 What:           /sys/class/thermal/cooling_dev    
217 Description:                                      
218                 The current cooling state of t    
219                 The value can any integer numb    
220                                                   
221                 - cur_state == 0 means no cool    
222                 - cur_state == max_state means    
223                                                   
224                 RW, Required                      
225                                                   
226 What:           /sys/class/thermal/cooling_dev    
227 Description:                                      
228                 Writing any value resets the c    
229                                                   
230                 WO, Required                      
231                                                   
232 What:           /sys/class/thermal/cooling_dev    
233 Description:                                      
234                 The amount of time spent by th    
235                 cooling states. The output wil    
236                 in each line, which will mean     
237                 msec of time at <state>.          
238                                                   
239                 Output will have one line for     
240                                                   
241                 RO, Required                      
242                                                   
243 What:           /sys/class/thermal/cooling_dev    
244 Description:                                      
245                 A single positive value showin    
246                 the state of a cooling device     
247                                                   
248                 RO, Required                      
249                                                   
250 What:           /sys/class/thermal/cooling_dev    
251 Description:                                      
252                 This gives fine grained inform    
253                 transitions. The cat output he    
254                 where an entry <i,j> (row i, c    
255                 of transitions from State_i to    
256                 table is bigger than PAGE_SIZE    
257                 an -EFBIG error.                  
258                                                   
259                 RO, Required                      
                                                      

~ [ source navigation ] ~ [ diff markup ] ~ [ identifier search ] ~

kernel.org | git.kernel.org | LWN.net | Project Home | SVN repository | Mail admin

Linux® is a registered trademark of Linus Torvalds in the United States and other countries.
TOMOYO® is a registered trademark of NTT DATA CORPORATION.

sflogo.php