~ [ source navigation ] ~ [ diff markup ] ~ [ identifier search ] ~

TOMOYO Linux Cross Reference
Linux/Documentation/devicetree/bindings/regulator/regulator.yaml

Version: ~ [ linux-6.12-rc7 ] ~ [ linux-6.11.7 ] ~ [ linux-6.10.14 ] ~ [ linux-6.9.12 ] ~ [ linux-6.8.12 ] ~ [ linux-6.7.12 ] ~ [ linux-6.6.60 ] ~ [ linux-6.5.13 ] ~ [ linux-6.4.16 ] ~ [ linux-6.3.13 ] ~ [ linux-6.2.16 ] ~ [ linux-6.1.116 ] ~ [ linux-6.0.19 ] ~ [ linux-5.19.17 ] ~ [ linux-5.18.19 ] ~ [ linux-5.17.15 ] ~ [ linux-5.16.20 ] ~ [ linux-5.15.171 ] ~ [ linux-5.14.21 ] ~ [ linux-5.13.19 ] ~ [ linux-5.12.19 ] ~ [ linux-5.11.22 ] ~ [ linux-5.10.229 ] ~ [ linux-5.9.16 ] ~ [ linux-5.8.18 ] ~ [ linux-5.7.19 ] ~ [ linux-5.6.19 ] ~ [ linux-5.5.19 ] ~ [ linux-5.4.285 ] ~ [ linux-5.3.18 ] ~ [ linux-5.2.21 ] ~ [ linux-5.1.21 ] ~ [ linux-5.0.21 ] ~ [ linux-4.20.17 ] ~ [ linux-4.19.323 ] ~ [ linux-4.18.20 ] ~ [ linux-4.17.19 ] ~ [ linux-4.16.18 ] ~ [ linux-4.15.18 ] ~ [ linux-4.14.336 ] ~ [ linux-4.13.16 ] ~ [ linux-4.12.14 ] ~ [ linux-4.11.12 ] ~ [ linux-4.10.17 ] ~ [ linux-4.9.337 ] ~ [ linux-4.4.302 ] ~ [ linux-3.10.108 ] ~ [ linux-2.6.32.71 ] ~ [ linux-2.6.0 ] ~ [ linux-2.4.37.11 ] ~ [ unix-v6-master ] ~ [ ccs-tools-1.8.12 ] ~ [ policy-sample ] ~
Architecture: ~ [ i386 ] ~ [ alpha ] ~ [ m68k ] ~ [ mips ] ~ [ ppc ] ~ [ sparc ] ~ [ sparc64 ] ~

Diff markup

Differences between /Documentation/devicetree/bindings/regulator/regulator.yaml (Architecture i386) and /Documentation/devicetree/bindings/regulator/regulator.yaml (Architecture ppc)


  1 # SPDX-License-Identifier: GPL-2.0                  1 # SPDX-License-Identifier: GPL-2.0
  2 %YAML 1.2                                           2 %YAML 1.2
  3 ---                                                 3 ---
  4 $id: http://devicetree.org/schemas/regulator/r      4 $id: http://devicetree.org/schemas/regulator/regulator.yaml#
  5 $schema: http://devicetree.org/meta-schemas/co      5 $schema: http://devicetree.org/meta-schemas/core.yaml#
  6                                                     6 
  7 title: Voltage/Current Regulators                   7 title: Voltage/Current Regulators
  8                                                     8 
  9 maintainers:                                        9 maintainers:
 10   - Liam Girdwood <lgirdwood@gmail.com>             10   - Liam Girdwood <lgirdwood@gmail.com>
 11   - Mark Brown <broonie@kernel.org>                 11   - Mark Brown <broonie@kernel.org>
 12                                                    12 
 13 properties:                                        13 properties:
 14   regulator-name:                                  14   regulator-name:
 15     description: A string used as a descriptiv     15     description: A string used as a descriptive name for regulator outputs
 16     $ref: /schemas/types.yaml#/definitions/str     16     $ref: /schemas/types.yaml#/definitions/string
 17                                                    17 
 18   regulator-min-microvolt:                         18   regulator-min-microvolt:
 19     description: smallest voltage consumers ma     19     description: smallest voltage consumers may set
 20                                                    20 
 21   regulator-max-microvolt:                         21   regulator-max-microvolt:
 22     description: largest voltage consumers may     22     description: largest voltage consumers may set
 23                                                    23 
 24   regulator-microvolt-offset:                      24   regulator-microvolt-offset:
 25     description: Offset applied to voltages to     25     description: Offset applied to voltages to compensate for voltage drops
 26     $ref: /schemas/types.yaml#/definitions/uin     26     $ref: /schemas/types.yaml#/definitions/uint32
 27                                                    27 
 28   regulator-min-microamp:                          28   regulator-min-microamp:
 29     description: smallest current consumers ma     29     description: smallest current consumers may set
 30                                                    30 
 31   regulator-max-microamp:                          31   regulator-max-microamp:
 32     description: largest current consumers may     32     description: largest current consumers may set
 33                                                    33 
 34   regulator-input-current-limit-microamp:          34   regulator-input-current-limit-microamp:
 35     description: maximum input current regulat     35     description: maximum input current regulator allows
 36                                                    36 
 37   regulator-always-on:                             37   regulator-always-on:
 38     description: boolean, regulator should nev     38     description: boolean, regulator should never be disabled
 39     type: boolean                                  39     type: boolean
 40                                                    40 
 41   regulator-boot-on:                               41   regulator-boot-on:
 42     description: bootloader/firmware enabled r     42     description: bootloader/firmware enabled regulator.
 43       It's expected that this regulator was le     43       It's expected that this regulator was left on by the bootloader.
 44       If the bootloader didn't leave it on the     44       If the bootloader didn't leave it on then OS should turn it on
 45       at boot but shouldn't prevent it from be     45       at boot but shouldn't prevent it from being turned off later.
 46       This property is intended to only be use     46       This property is intended to only be used for regulators where
 47       software cannot read the state of the re     47       software cannot read the state of the regulator.
 48     type: boolean                                  48     type: boolean
 49                                                    49 
 50   regulator-allow-bypass:                          50   regulator-allow-bypass:
 51     description: allow the regulator to go int     51     description: allow the regulator to go into bypass mode
 52     type: boolean                                  52     type: boolean
 53                                                    53 
 54   regulator-allow-set-load:                        54   regulator-allow-set-load:
 55     description: allow the regulator performan     55     description: allow the regulator performance level to be configured
 56     type: boolean                                  56     type: boolean
 57                                                    57 
 58   regulator-ramp-delay:                            58   regulator-ramp-delay:
 59     description: ramp delay for regulator(in u     59     description: ramp delay for regulator(in uV/us) For hardware which supports
 60       disabling ramp rate, it should be explic     60       disabling ramp rate, it should be explicitly initialised to zero (regulator-ramp-delay
 61       = <0>) for disabling ramp delay.             61       = <0>) for disabling ramp delay.
 62     $ref: /schemas/types.yaml#/definitions/uin     62     $ref: /schemas/types.yaml#/definitions/uint32
 63                                                    63 
 64   regulator-enable-ramp-delay:                     64   regulator-enable-ramp-delay:
 65     description: The time taken, in microsecon     65     description: The time taken, in microseconds, for the supply rail to
 66       reach the target voltage, plus/minus wha     66       reach the target voltage, plus/minus whatever tolerance the board
 67       design requires. This property describes     67       design requires. This property describes the total system ramp time
 68       required due to the combination of inter     68       required due to the combination of internal ramping of the regulator
 69       itself, and board design issues such as      69       itself, and board design issues such as trace capacitance and load
 70       on the supply.                               70       on the supply.
 71     $ref: /schemas/types.yaml#/definitions/uin     71     $ref: /schemas/types.yaml#/definitions/uint32
 72                                                    72 
 73   regulator-settling-time-us:                      73   regulator-settling-time-us:
 74     description: Settling time, in microsecond     74     description: Settling time, in microseconds, for voltage change if regulator
 75       have the constant time for any level vol     75       have the constant time for any level voltage change. This is useful
 76       when regulator have exponential voltage      76       when regulator have exponential voltage change.
 77                                                    77 
 78   regulator-settling-time-up-us:                   78   regulator-settling-time-up-us:
 79     description: Settling time, in microsecond     79     description: Settling time, in microseconds, for voltage increase if
 80       the regulator needs a constant time to s     80       the regulator needs a constant time to settle after voltage increases
 81       of any level. This is useful for regulat     81       of any level. This is useful for regulators with exponential voltage
 82       changes.                                     82       changes.
 83                                                    83 
 84   regulator-settling-time-down-us:                 84   regulator-settling-time-down-us:
 85     description: Settling time, in microsecond     85     description: Settling time, in microseconds, for voltage decrease if
 86       the regulator needs a constant time to s     86       the regulator needs a constant time to settle after voltage decreases
 87       of any level. This is useful for regulat     87       of any level. This is useful for regulators with exponential voltage
 88       changes.                                     88       changes.
 89                                                    89 
 90   regulator-soft-start:                            90   regulator-soft-start:
 91     description: Enable soft start so that vol     91     description: Enable soft start so that voltage ramps slowly
 92     type: boolean                                  92     type: boolean
 93                                                    93 
 94   regulator-initial-mode:                          94   regulator-initial-mode:
 95     description: initial operating mode. The s     95     description: initial operating mode. The set of possible operating modes
 96       depends on the capabilities of every har     96       depends on the capabilities of every hardware so each device binding
 97       documentation explains which values the      97       documentation explains which values the regulator supports.
 98     $ref: /schemas/types.yaml#/definitions/uin     98     $ref: /schemas/types.yaml#/definitions/uint32
 99                                                    99 
100   regulator-allowed-modes:                        100   regulator-allowed-modes:
101     description: list of operating modes that     101     description: list of operating modes that software is allowed to configure
102       for the regulator at run-time.  Elements    102       for the regulator at run-time.  Elements may be specified in any order.
103       The set of possible operating modes depe    103       The set of possible operating modes depends on the capabilities of
104       every hardware so each device binding do    104       every hardware so each device binding document explains which values
105       the regulator supports.                     105       the regulator supports.
106     $ref: /schemas/types.yaml#/definitions/uin    106     $ref: /schemas/types.yaml#/definitions/uint32-array
107                                                   107 
108   regulator-system-load:                          108   regulator-system-load:
109     description: Load in uA present on regulat    109     description: Load in uA present on regulator that is not captured by
110       any consumer request.                       110       any consumer request.
111     $ref: /schemas/types.yaml#/definitions/uin    111     $ref: /schemas/types.yaml#/definitions/uint32
112                                                   112 
113   regulator-pull-down:                            113   regulator-pull-down:
114     description: Enable pull down resistor whe    114     description: Enable pull down resistor when the regulator is disabled.
115     type: boolean                                 115     type: boolean
116                                                   116 
117   system-critical-regulator:                      117   system-critical-regulator:
118     description: Set if the regulator is criti    118     description: Set if the regulator is critical to system stability or
119       functionality.                              119       functionality.
120     type: boolean                                 120     type: boolean
121                                                   121 
122   regulator-over-current-protection:              122   regulator-over-current-protection:
123     description: Enable over current protectio    123     description: Enable over current protection.
124     type: boolean                                 124     type: boolean
125                                                   125 
126   regulator-oc-protection-microamp:               126   regulator-oc-protection-microamp:
127     description: Set over current protection l    127     description: Set over current protection limit. This is a limit where
128       hardware performs emergency shutdown. Ze    128       hardware performs emergency shutdown. Zero can be passed to disable
129       protection and value '1' indicates that     129       protection and value '1' indicates that protection should be enabled but
130       limit setting can be omitted.               130       limit setting can be omitted.
131                                                   131 
132   regulator-oc-error-microamp:                    132   regulator-oc-error-microamp:
133     description: Set over current error limit.    133     description: Set over current error limit. This is a limit where part of
134       the hardware probably is malfunctional a    134       the hardware probably is malfunctional and damage prevention is requested.
135       Zero can be passed to disable error dete    135       Zero can be passed to disable error detection and value '1' indicates
136       that detection should be enabled but lim    136       that detection should be enabled but limit setting can be omitted.
137                                                   137 
138   regulator-oc-warn-microamp:                     138   regulator-oc-warn-microamp:
139     description: Set over current warning limi    139     description: Set over current warning limit. This is a limit where hardware
140       is assumed still to be functional but ap    140       is assumed still to be functional but approaching limit where it gets
141       damaged. Recovery actions should be init    141       damaged. Recovery actions should be initiated. Zero can be passed to
142       disable detection and value '1' indicate    142       disable detection and value '1' indicates that detection should
143       be enabled but limit setting can be omit    143       be enabled but limit setting can be omitted.
144                                                   144 
145   regulator-ov-protection-microvolt:              145   regulator-ov-protection-microvolt:
146     description: Set over voltage protection l    146     description: Set over voltage protection limit. This is a limit where
147       hardware performs emergency shutdown. Ze    147       hardware performs emergency shutdown. Zero can be passed to disable
148       protection and value '1' indicates that     148       protection and value '1' indicates that protection should be enabled but
149       limit setting can be omitted. Limit is g    149       limit setting can be omitted. Limit is given as microvolt offset from
150       voltage set to regulator.                   150       voltage set to regulator.
151                                                   151 
152   regulator-ov-error-microvolt:                   152   regulator-ov-error-microvolt:
153     description: Set over voltage error limit.    153     description: Set over voltage error limit. This is a limit where part of
154       the hardware probably is malfunctional a    154       the hardware probably is malfunctional and damage prevention is requested
155       Zero can be passed to disable error dete    155       Zero can be passed to disable error detection and value '1' indicates
156       that detection should be enabled but lim    156       that detection should be enabled but limit setting can be omitted. Limit
157       is given as microvolt offset from voltag    157       is given as microvolt offset from voltage set to regulator.
158                                                   158 
159   regulator-ov-warn-microvolt:                    159   regulator-ov-warn-microvolt:
160     description: Set over voltage warning limi    160     description: Set over voltage warning limit. This is a limit where hardware
161       is assumed still to be functional but ap    161       is assumed still to be functional but approaching limit where it gets
162       damaged. Recovery actions should be init    162       damaged. Recovery actions should be initiated. Zero can be passed to
163       disable detection and value '1' indicate    163       disable detection and value '1' indicates that detection should
164       be enabled but limit setting can be omit    164       be enabled but limit setting can be omitted. Limit is given as microvolt
165       offset from voltage set to regulator.       165       offset from voltage set to regulator.
166                                                   166 
167   regulator-uv-protection-microvolt:              167   regulator-uv-protection-microvolt:
168     description: Set over under voltage protec    168     description: Set over under voltage protection limit. This is a limit where
169       hardware performs emergency shutdown. Ze    169       hardware performs emergency shutdown. Zero can be passed to disable
170       protection and value '1' indicates that     170       protection and value '1' indicates that protection should be enabled but
171       limit setting can be omitted. Limit is g    171       limit setting can be omitted. Limit is given as microvolt offset from
172       voltage set to regulator.                   172       voltage set to regulator.
173                                                   173 
174   regulator-uv-error-microvolt:                   174   regulator-uv-error-microvolt:
175     description: Set under voltage error limit    175     description: Set under voltage error limit. This is a limit where part of
176       the hardware probably is malfunctional a    176       the hardware probably is malfunctional and damage prevention is requested
177       Zero can be passed to disable error dete    177       Zero can be passed to disable error detection and value '1' indicates
178       that detection should be enabled but lim    178       that detection should be enabled but limit setting can be omitted. Limit
179       is given as microvolt offset from voltag    179       is given as microvolt offset from voltage set to regulator.
180                                                   180 
181   regulator-uv-warn-microvolt:                    181   regulator-uv-warn-microvolt:
182     description: Set over under voltage warnin    182     description: Set over under voltage warning limit. This is a limit where
183       hardware is assumed still to be function    183       hardware is assumed still to be functional but approaching limit where
184       it gets damaged. Recovery actions should    184       it gets damaged. Recovery actions should be initiated. Zero can be passed
185       to disable detection and value '1' indic    185       to disable detection and value '1' indicates that detection should
186       be enabled but limit setting can be omit    186       be enabled but limit setting can be omitted. Limit is given as microvolt
187       offset from voltage set to regulator.       187       offset from voltage set to regulator.
188                                                   188 
189   regulator-uv-less-critical-window-ms:           189   regulator-uv-less-critical-window-ms:
190     description: Specifies the time window (in    190     description: Specifies the time window (in milliseconds) following a
191       critical under-voltage event during whic    191       critical under-voltage event during which the system can continue to
192       operate safely while performing less cri    192       operate safely while performing less critical operations. This property
193       provides a defined duration before a mor    193       provides a defined duration before a more severe reaction to the
194       under-voltage event is needed, allowing     194       under-voltage event is needed, allowing for certain non-urgent actions to
195       be carried out in preparation for potent    195       be carried out in preparation for potential power loss.
196                                                   196 
197   regulator-temp-protection-kelvin:               197   regulator-temp-protection-kelvin:
198     description: Set over temperature protecti    198     description: Set over temperature protection limit. This is a limit where
199       hardware performs emergency shutdown. Ze    199       hardware performs emergency shutdown. Zero can be passed to disable
200       protection and value '1' indicates that     200       protection and value '1' indicates that protection should be enabled but
201       limit setting can be omitted.               201       limit setting can be omitted.
202                                                   202 
203   regulator-temp-error-kelvin:                    203   regulator-temp-error-kelvin:
204     description: Set over temperature error li    204     description: Set over temperature error limit. This is a limit where part of
205       the hardware probably is malfunctional a    205       the hardware probably is malfunctional and damage prevention is requested
206       Zero can be passed to disable error dete    206       Zero can be passed to disable error detection and value '1' indicates
207       that detection should be enabled but lim    207       that detection should be enabled but limit setting can be omitted.
208                                                   208 
209   regulator-temp-warn-kelvin:                     209   regulator-temp-warn-kelvin:
210     description: Set over temperature warning     210     description: Set over temperature warning limit. This is a limit where
211       hardware is assumed still to be function    211       hardware is assumed still to be functional but approaching limit where it
212       gets damaged. Recovery actions should be    212       gets damaged. Recovery actions should be initiated. Zero can be passed to
213       disable detection and value '1' indicate    213       disable detection and value '1' indicates that detection should
214       be enabled but limit setting can be omit    214       be enabled but limit setting can be omitted.
215                                                   215 
216   regulator-active-discharge:                     216   regulator-active-discharge:
217     description: |                                217     description: |
218       tristate, enable/disable active discharg    218       tristate, enable/disable active discharge of regulators. The values are:
219       0: Disable active discharge.                219       0: Disable active discharge.
220       1: Enable active discharge.                 220       1: Enable active discharge.
221       Absence of this property will leave conf    221       Absence of this property will leave configuration to default.
222     $ref: /schemas/types.yaml#/definitions/uin    222     $ref: /schemas/types.yaml#/definitions/uint32
223     enum: [0, 1]                                  223     enum: [0, 1]
224                                                   224 
225   regulator-coupled-with:                         225   regulator-coupled-with:
226     description: Regulators with which the reg    226     description: Regulators with which the regulator is coupled. The linkage
227       is 2-way - all coupled regulators should    227       is 2-way - all coupled regulators should be linked with each other.
228       A regulator should not be coupled with i    228       A regulator should not be coupled with its supplier.
229     $ref: /schemas/types.yaml#/definitions/pha    229     $ref: /schemas/types.yaml#/definitions/phandle-array
230     items:                                        230     items:
231       maxItems: 1                                 231       maxItems: 1
232                                                   232 
233   regulator-coupled-max-spread:                   233   regulator-coupled-max-spread:
234     description: Array of maximum spread betwe    234     description: Array of maximum spread between voltages of coupled regulators
235       in microvolts, each value in the array r    235       in microvolts, each value in the array relates to the corresponding
236       couple specified by the regulator-couple    236       couple specified by the regulator-coupled-with property.
237     $ref: /schemas/types.yaml#/definitions/uin    237     $ref: /schemas/types.yaml#/definitions/uint32-array
238                                                   238 
239   regulator-max-step-microvolt:                   239   regulator-max-step-microvolt:
240     description: Maximum difference between cu    240     description: Maximum difference between current and target voltages
241       that can be changed safely in a single s    241       that can be changed safely in a single step.
242                                                   242 
243 patternProperties:                                243 patternProperties:
244   ".*-supply$":                                   244   ".*-supply$":
245     description: Input supply phandle(s) for t    245     description: Input supply phandle(s) for this node
246                                                   246 
247   "^regulator-state-(standby|mem|disk)$":         247   "^regulator-state-(standby|mem|disk)$":
248     type: object                                  248     type: object
249     description:                                  249     description:
250       sub-nodes for regulator state in Standby    250       sub-nodes for regulator state in Standby, Suspend-to-RAM, and
251       Suspend-to-DISK modes. Equivalent with s    251       Suspend-to-DISK modes. Equivalent with standby, mem, and disk Linux
252       sleep states.                               252       sleep states.
253                                                   253 
254     properties:                                   254     properties:
255       regulator-on-in-suspend:                    255       regulator-on-in-suspend:
256         description: regulator should be on in    256         description: regulator should be on in suspend state.
257         type: boolean                             257         type: boolean
258                                                   258 
259       regulator-off-in-suspend:                   259       regulator-off-in-suspend:
260         description: regulator should be off i    260         description: regulator should be off in suspend state.
261         type: boolean                             261         type: boolean
262                                                   262 
263       regulator-suspend-min-microvolt:            263       regulator-suspend-min-microvolt:
264         description: minimum voltage may be se    264         description: minimum voltage may be set in suspend state.
265                                                   265 
266       regulator-suspend-max-microvolt:            266       regulator-suspend-max-microvolt:
267         description: maximum voltage may be se    267         description: maximum voltage may be set in suspend state.
268                                                   268 
269       regulator-suspend-microvolt:                269       regulator-suspend-microvolt:
270         description: the default voltage which    270         description: the default voltage which regulator would be set in
271           suspend. This property is now deprec    271           suspend. This property is now deprecated, instead setting voltage
272           for suspend mode via the API which r    272           for suspend mode via the API which regulator driver provides is
273           recommended.                            273           recommended.
274                                                   274 
275       regulator-changeable-in-suspend:            275       regulator-changeable-in-suspend:
276         description: whether the default volta    276         description: whether the default voltage and the regulator on/off
277           in suspend can be changed in runtime    277           in suspend can be changed in runtime.
278         type: boolean                             278         type: boolean
279                                                   279 
280       regulator-mode:                             280       regulator-mode:
281         description: operating mode in the giv    281         description: operating mode in the given suspend state. The set
282           of possible operating modes depends     282           of possible operating modes depends on the capabilities of every
283           hardware so the valid modes are docu    283           hardware so the valid modes are documented on each regulator device
284           tree binding document.                  284           tree binding document.
285         $ref: /schemas/types.yaml#/definitions    285         $ref: /schemas/types.yaml#/definitions/uint32
286                                                   286 
287     additionalProperties: false                   287     additionalProperties: false
288                                                   288 
289 additionalProperties: true                        289 additionalProperties: true
290                                                   290 
291 examples:                                         291 examples:
292   - |                                             292   - |
293     xyzreg: regulator {                           293     xyzreg: regulator {
294       regulator-min-microvolt = <1000000>;        294       regulator-min-microvolt = <1000000>;
295       regulator-max-microvolt = <2500000>;        295       regulator-max-microvolt = <2500000>;
296       regulator-always-on;                        296       regulator-always-on;
297       vin-supply = <&vin>;                        297       vin-supply = <&vin>;
298                                                   298 
299       regulator-state-mem {                       299       regulator-state-mem {
300         regulator-on-in-suspend;                  300         regulator-on-in-suspend;
301       };                                          301       };
302     };                                            302     };
303                                                   303 
304 ...                                               304 ...
                                                      

~ [ source navigation ] ~ [ diff markup ] ~ [ identifier search ] ~

kernel.org | git.kernel.org | LWN.net | Project Home | SVN repository | Mail admin

Linux® is a registered trademark of Linus Torvalds in the United States and other countries.
TOMOYO® is a registered trademark of NTT DATA CORPORATION.

sflogo.php