Version: ~ [ linux-6.12-rc7 ] ~ [ linux-6.11.7 ] ~ [ linux-6.10.14 ] ~ [ linux-6.9.12 ] ~ [ linux-6.8.12 ] ~ [ linux-6.7.12 ] ~ [ linux-6.6.60 ] ~ [ linux-6.5.13 ] ~ [ linux-6.4.16 ] ~ [ linux-6.3.13 ] ~ [ linux-6.2.16 ] ~ [ linux-6.1.116 ] ~ [ linux-6.0.19 ] ~ [ linux-5.19.17 ] ~ [ linux-5.18.19 ] ~ [ linux-5.17.15 ] ~ [ linux-5.16.20 ] ~ [ linux-5.15.171 ] ~ [ linux-5.14.21 ] ~ [ linux-5.13.19 ] ~ [ linux-5.12.19 ] ~ [ linux-5.11.22 ] ~ [ linux-5.10.229 ] ~ [ linux-5.9.16 ] ~ [ linux-5.8.18 ] ~ [ linux-5.7.19 ] ~ [ linux-5.6.19 ] ~ [ linux-5.5.19 ] ~ [ linux-5.4.285 ] ~ [ linux-5.3.18 ] ~ [ linux-5.2.21 ] ~ [ linux-5.1.21 ] ~ [ linux-5.0.21 ] ~ [ linux-4.20.17 ] ~ [ linux-4.19.323 ] ~ [ linux-4.18.20 ] ~ [ linux-4.17.19 ] ~ [ linux-4.16.18 ] ~ [ linux-4.15.18 ] ~ [ linux-4.14.336 ] ~ [ linux-4.13.16 ] ~ [ linux-4.12.14 ] ~ [ linux-4.11.12 ] ~ [ linux-4.10.17 ] ~ [ linux-4.9.337 ] ~ [ linux-4.4.302 ] ~ [ linux-3.10.108 ] ~ [ linux-2.6.32.71 ] ~ [ linux-2.6.0 ] ~ [ linux-2.4.37.11 ] ~ [ unix-v6-master ] ~ [ ccs-tools-1.8.12 ] ~ [ policy-sample ] ~
Architecture: ~ [ i386 ] ~ [ alpha ] ~ [ m68k ] ~ [ mips ] ~ [ ppc ] ~ [ sparc ] ~ [ sparc64 ] ~

Diff markup

Differences between /Documentation/networking/pse-pd/introduction.rst (Architecture m68k) and /Documentation/networking/pse-pd/introduction.rst (Architecture ppc)


  1 .. SPDX-License-Identifier: GPL-2.0                 1 .. SPDX-License-Identifier: GPL-2.0
  2                                                     2 
  3 Power Sourcing Equipment (PSE) in IEEE 802.3 S      3 Power Sourcing Equipment (PSE) in IEEE 802.3 Standard
  4 ==============================================      4 =====================================================
  5                                                     5 
  6 Overview                                            6 Overview
  7 --------                                            7 --------
  8                                                     8 
  9 Power Sourcing Equipment (PSE) is essential in      9 Power Sourcing Equipment (PSE) is essential in networks for delivering power
 10 along with data over Ethernet cables. It usual     10 along with data over Ethernet cables. It usually refers to devices like
 11 switches and hubs that supply power to Powered     11 switches and hubs that supply power to Powered Devices (PDs) such as IP
 12 cameras, VoIP phones, and wireless access poin     12 cameras, VoIP phones, and wireless access points.
 13                                                    13 
 14 PSE vs. PoDL PSE                                   14 PSE vs. PoDL PSE
 15 ----------------                                   15 ----------------
 16                                                    16 
 17 PSE in the IEEE 802.3 standard generally refer     17 PSE in the IEEE 802.3 standard generally refers to equipment that provides
 18 power alongside data over Ethernet cables, typ     18 power alongside data over Ethernet cables, typically associated with Power over
 19 Ethernet (PoE).                                    19 Ethernet (PoE).
 20                                                    20 
 21 PoDL PSE, or Power over Data Lines PSE, specif     21 PoDL PSE, or Power over Data Lines PSE, specifically denotes PSEs operating
 22 with single balanced twisted-pair PHYs, as per     22 with single balanced twisted-pair PHYs, as per Clause 104 of IEEE 802.3. PoDL
 23 is significant in contexts like automotive and     23 is significant in contexts like automotive and industrial controls where power
 24 and data delivery over a single pair is advant     24 and data delivery over a single pair is advantageous.
 25                                                    25 
 26 IEEE 802.3-2018 Addendums and Related Clauses      26 IEEE 802.3-2018 Addendums and Related Clauses
 27 ---------------------------------------------      27 ---------------------------------------------
 28                                                    28 
 29 Key addenda to the IEEE 802.3-2018 standard re     29 Key addenda to the IEEE 802.3-2018 standard relevant to power delivery over
 30 Ethernet are as follows:                           30 Ethernet are as follows:
 31                                                    31 
 32 - **802.3af (Approved in 2003-06-12)**: Known      32 - **802.3af (Approved in 2003-06-12)**: Known as PoE in the market, detailed in
 33   Clause 33, delivering up to 15.4W of power.      33   Clause 33, delivering up to 15.4W of power.
 34 - **802.3at (Approved in 2009-09-11)**: Market     34 - **802.3at (Approved in 2009-09-11)**: Marketed as PoE+, enhancing PoE as
 35   covered in Clause 33, increasing power deliv     35   covered in Clause 33, increasing power delivery to up to 30W.
 36 - **802.3bt (Approved in 2018-09-27)**: Known      36 - **802.3bt (Approved in 2018-09-27)**: Known as 4PPoE in the market, outlined
 37   in Clause 33. Type 3 delivers up to 60W, and     37   in Clause 33. Type 3 delivers up to 60W, and Type 4 up to 100W.
 38 - **802.3bu (Approved in 2016-12-07)**: Former     38 - **802.3bu (Approved in 2016-12-07)**: Formerly referred to as PoDL, detailed
 39   in Clause 104. Introduces Classes 0 - 9. Cla     39   in Clause 104. Introduces Classes 0 - 9. Class 9 PoDL PSE delivers up to ~65W
 40                                                    40 
 41 Kernel Naming Convention Recommendations           41 Kernel Naming Convention Recommendations
 42 ----------------------------------------           42 ----------------------------------------
 43                                                    43 
 44 For clarity and consistency within the Linux k     44 For clarity and consistency within the Linux kernel's networking subsystem, the
 45 following naming conventions are recommended:      45 following naming conventions are recommended:
 46                                                    46 
 47 - For general PSE (PoE) code, use "c33_pse" ke     47 - For general PSE (PoE) code, use "c33_pse" key words. For example:
 48   ``enum ethtool_c33_pse_admin_state c33_admin     48   ``enum ethtool_c33_pse_admin_state c33_admin_control;``.
 49   This aligns with Clause 33, encompassing var     49   This aligns with Clause 33, encompassing various PoE forms.
 50                                                    50 
 51 - For PoDL PSE - specific code, use "podl_pse"     51 - For PoDL PSE - specific code, use "podl_pse". For example:
 52   ``enum ethtool_podl_pse_admin_state podl_adm     52   ``enum ethtool_podl_pse_admin_state podl_admin_control;`` to differentiate
 53   PoDL PSE settings according to Clause 104.       53   PoDL PSE settings according to Clause 104.
 54                                                    54 
 55 Summary of Clause 33: Data Terminal Equipment      55 Summary of Clause 33: Data Terminal Equipment (DTE) Power via Media Dependent Interface (MDI)
 56 ----------------------------------------------     56 ---------------------------------------------------------------------------------------------
 57                                                    57 
 58 Clause 33 of the IEEE 802.3 standard defines t     58 Clause 33 of the IEEE 802.3 standard defines the functional and electrical
 59 characteristics of Powered Device (PD) and Pow     59 characteristics of Powered Device (PD) and Power Sourcing Equipment (PSE).
 60 These entities enable power delivery using the     60 These entities enable power delivery using the same generic cabling as for data
 61 transmission, integrating power with data comm     61 transmission, integrating power with data communication for devices such as
 62 10BASE-T, 100BASE-TX, or 1000BASE-T.               62 10BASE-T, 100BASE-TX, or 1000BASE-T.
 63                                                    63 
 64 Summary of Clause 104: Power over Data Lines (     64 Summary of Clause 104: Power over Data Lines (PoDL) of Single Balanced Twisted-Pair Ethernet
 65 ----------------------------------------------     65 --------------------------------------------------------------------------------------------
 66                                                    66 
 67 Clause 104 of the IEEE 802.3 standard delineat     67 Clause 104 of the IEEE 802.3 standard delineates the functional and electrical
 68 characteristics of PoDL Powered Devices (PDs)      68 characteristics of PoDL Powered Devices (PDs) and PoDL Power Sourcing Equipment
 69 (PSEs). These are designed for use with single     69 (PSEs). These are designed for use with single balanced twisted-pair Ethernet
 70 Physical Layers. In this clause, 'PSE' refers      70 Physical Layers. In this clause, 'PSE' refers specifically to PoDL PSE, and
 71 'PD' to PoDL PD. The key intent is to provide      71 'PD' to PoDL PD. The key intent is to provide devices with a unified interface
 72 for both data and the power required to proces     72 for both data and the power required to process this data over a single
 73 balanced twisted-pair Ethernet connection.         73 balanced twisted-pair Ethernet connection.
                                                      