~ [ source navigation ] ~ [ diff markup ] ~ [ identifier search ] ~

TOMOYO Linux Cross Reference
Linux/tools/thermal/tmon/tmon.8

Version: ~ [ linux-6.12-rc7 ] ~ [ linux-6.11.7 ] ~ [ linux-6.10.14 ] ~ [ linux-6.9.12 ] ~ [ linux-6.8.12 ] ~ [ linux-6.7.12 ] ~ [ linux-6.6.60 ] ~ [ linux-6.5.13 ] ~ [ linux-6.4.16 ] ~ [ linux-6.3.13 ] ~ [ linux-6.2.16 ] ~ [ linux-6.1.116 ] ~ [ linux-6.0.19 ] ~ [ linux-5.19.17 ] ~ [ linux-5.18.19 ] ~ [ linux-5.17.15 ] ~ [ linux-5.16.20 ] ~ [ linux-5.15.171 ] ~ [ linux-5.14.21 ] ~ [ linux-5.13.19 ] ~ [ linux-5.12.19 ] ~ [ linux-5.11.22 ] ~ [ linux-5.10.229 ] ~ [ linux-5.9.16 ] ~ [ linux-5.8.18 ] ~ [ linux-5.7.19 ] ~ [ linux-5.6.19 ] ~ [ linux-5.5.19 ] ~ [ linux-5.4.285 ] ~ [ linux-5.3.18 ] ~ [ linux-5.2.21 ] ~ [ linux-5.1.21 ] ~ [ linux-5.0.21 ] ~ [ linux-4.20.17 ] ~ [ linux-4.19.323 ] ~ [ linux-4.18.20 ] ~ [ linux-4.17.19 ] ~ [ linux-4.16.18 ] ~ [ linux-4.15.18 ] ~ [ linux-4.14.336 ] ~ [ linux-4.13.16 ] ~ [ linux-4.12.14 ] ~ [ linux-4.11.12 ] ~ [ linux-4.10.17 ] ~ [ linux-4.9.337 ] ~ [ linux-4.4.302 ] ~ [ linux-3.10.108 ] ~ [ linux-2.6.32.71 ] ~ [ linux-2.6.0 ] ~ [ linux-2.4.37.11 ] ~ [ unix-v6-master ] ~ [ ccs-tools-1.8.12 ] ~ [ policy-sample ] ~
Architecture: ~ [ i386 ] ~ [ alpha ] ~ [ m68k ] ~ [ mips ] ~ [ ppc ] ~ [ sparc ] ~ [ sparc64 ] ~

Diff markup

Differences between /tools/thermal/tmon/tmon.8 (Version linux-6.12-rc7) and /tools/thermal/tmon/tmon.8 (Version linux-4.18.20)


  1 .TH TMON 8                                          1 .TH TMON 8
  2 # SPDX-License-Identifier: GPL-2.0                  2 # SPDX-License-Identifier: GPL-2.0
  3 .SH NAME                                            3 .SH NAME
  4 \fBtmon\fP - A monitoring and testing tool for      4 \fBtmon\fP - A monitoring and testing tool for Linux kernel thermal subsystem
  5                                                     5 
  6 .SH SYNOPSIS                                        6 .SH SYNOPSIS
  7 .ft B                                               7 .ft B
  8 .B tmon                                             8 .B tmon
  9 .RB [ Options ]                                     9 .RB [ Options ]
 10 .br                                                10 .br
 11 .SH DESCRIPTION                                    11 .SH DESCRIPTION
 12 \fBtmon \fP can be used to visualize thermal r     12 \fBtmon \fP can be used to visualize thermal relationship and
 13 real-time thermal data; tune                       13 real-time thermal data; tune
 14 and test cooling devices and sensors; collect      14 and test cooling devices and sensors; collect thermal data for offline
 15 analysis and plot. \fBtmon\fP must be run as r     15 analysis and plot. \fBtmon\fP must be run as root in order to control device
 16 states via sysfs.                                  16 states via sysfs.
 17 .PP                                                17 .PP
 18 \fBFunctions\fP                                    18 \fBFunctions\fP
 19 .PP                                                19 .PP
 20 .nf                                                20 .nf
 21 1. Thermal relationships:                          21 1. Thermal relationships:
 22 - show thermal zone information                    22 - show thermal zone information
 23 - show cooling device information                  23 - show cooling device information
 24 - show trip point binding within each thermal      24 - show trip point binding within each thermal zone
 25 - show trip point and cooling device instance      25 - show trip point and cooling device instance bindings
 26 .PP                                                26 .PP
 27 2. Real time data display                          27 2. Real time data display
 28 - show temperature of all thermal zones w.r.t.     28 - show temperature of all thermal zones w.r.t. its trip points and types
 29 - show states of all cooling devices               29 - show states of all cooling devices
 30 .PP                                                30 .PP
 31 3. Thermal relationship learning and device tu     31 3. Thermal relationship learning and device tuning
 32 - with a built-in Proportional Integral Deriva     32 - with a built-in Proportional Integral Derivative (\fBPID\fP)
 33 controller, user can pair a cooling device to      33 controller, user can pair a cooling device to a thermal sensor for
 34 testing the effectiveness and learn about the      34 testing the effectiveness and learn about the thermal distance between the two
 35 - allow manual control of cooling device state     35 - allow manual control of cooling device states and target temperature
 36 .PP                                                36 .PP
 37 4. Data logging in /var/tmp/tmon.log               37 4. Data logging in /var/tmp/tmon.log
 38 - contains thermal configuration data, i.e. co     38 - contains thermal configuration data, i.e. cooling device, thermal
 39  zones, and trip points. Can be used for data      39  zones, and trip points. Can be used for data  collection in remote
 40  debugging.                                        40  debugging.
 41 - log real-time thermal data into space separa     41 - log real-time thermal data into space separated format that can be
 42  directly consumed by plotting tools such as R     42  directly consumed by plotting tools such as Rscript.
 43                                                    43 
 44 .SS Options                                        44 .SS Options
 45 .PP                                                45 .PP
 46 The \fB-c --control\fP option sets a cooling d     46 The \fB-c --control\fP option sets a cooling device type to control temperature
 47 of a thermal zone                                  47 of a thermal zone
 48 .PP                                                48 .PP
 49 The \fB-d --daemon\fP option runs \fBtmon \fP      49 The \fB-d --daemon\fP option runs \fBtmon \fP as daemon without user interface
 50 .PP                                                50 .PP
 51 The \fB-g --debug\fP option allow debug messag     51 The \fB-g --debug\fP option allow debug messages to be stored in syslog
 52 .PP                                                52 .PP
 53 The \fB-h --help\fP option shows help message      53 The \fB-h --help\fP option shows help message
 54 .PP                                                54 .PP
 55 The \fB-l --log\fP option write data to /var/t     55 The \fB-l --log\fP option write data to /var/tmp/tmon.log
 56 .PP                                                56 .PP
 57 The \fB-t --time-interval\fP option sets the p     57 The \fB-t --time-interval\fP option sets the polling interval in seconds
 58 .PP                                                58 .PP
 59 The \fB-T --target-temp\fP option sets the ini     59 The \fB-T --target-temp\fP option sets the initial target temperature
 60 .PP                                                60 .PP
 61 The \fB-v --version\fP option shows the versio     61 The \fB-v --version\fP option shows the version of \fBtmon \fP
 62 .PP                                                62 .PP
 63 The \fB-z --zone\fP option sets the target the     63 The \fB-z --zone\fP option sets the target therma zone instance to be controlled
 64 .PP                                                64 .PP
 65                                                    65 
 66 .SH FIELD DESCRIPTIONS                             66 .SH FIELD DESCRIPTIONS
 67 .nf                                                67 .nf
 68 .PP                                                68 .PP
 69 \fBP \fP passive cooling trip point type           69 \fBP \fP passive cooling trip point type
 70 \fBA \fP active cooling trip point type (fan)      70 \fBA \fP active cooling trip point type (fan)
 71 \fBC \fP critical trip point type                  71 \fBC \fP critical trip point type
 72 \fBA \fP hot trip point type                       72 \fBA \fP hot trip point type
 73 \fBkp \fP proportional gain of \fBPID\fP contr     73 \fBkp \fP proportional gain of \fBPID\fP controller
 74 \fBki \fP integral gain of \fBPID\fP controlle     74 \fBki \fP integral gain of \fBPID\fP controller
 75 \fBkd \fP derivative gain of \fBPID\fP control     75 \fBkd \fP derivative gain of \fBPID\fP controller
 76                                                    76 
 77 .SH REQUIREMENT                                    77 .SH REQUIREMENT
 78 Build depends on ncurses                           78 Build depends on ncurses
 79 .PP                                                79 .PP
 80 Runtime depends on window size large enough to     80 Runtime depends on window size large enough to show the number of
 81 devices found on the system.                       81 devices found on the system.
 82                                                    82 
 83 .PP                                                83 .PP
 84                                                    84 
 85 .SH INTERACTIVE COMMANDS                           85 .SH INTERACTIVE COMMANDS
 86 .pp                                                86 .pp
 87 .nf                                                87 .nf
 88 \fBCtrl-C, q/Q\fP stops \fBtmon\fP                 88 \fBCtrl-C, q/Q\fP stops \fBtmon\fP
 89 \fBTAB\fP shows tuning pop up panel, choose a      89 \fBTAB\fP shows tuning pop up panel, choose a letter to modify
 90                                                    90 
 91 .SH EXAMPLES                                       91 .SH EXAMPLES
 92 Without any parameters, tmon is in monitoring      92 Without any parameters, tmon is in monitoring only mode and refresh
 93 screen every 1 second.                             93 screen every 1 second.
 94 .PP                                                94 .PP
 95 1. For monitoring only:                            95 1. For monitoring only:
 96 .nf                                                96 .nf
 97 $ sudo ./tmon                                      97 $ sudo ./tmon
 98                                                    98 
 99 2. Use Processor cooling device to control the     99 2. Use Processor cooling device to control thermal zone 0 at default 65C.
100 $ sudo ./tmon -c Processor -z 0                   100 $ sudo ./tmon -c Processor -z 0
101                                                   101 
102 3. Use intel_powerclamp(idle injection) coolin    102 3. Use intel_powerclamp(idle injection) cooling device to control thermal zone 1
103 $ sudo ./tmon -c intel_powerclamp -z 1            103 $ sudo ./tmon -c intel_powerclamp -z 1
104                                                   104 
105 4. Turn on debug and collect data log at /var/    105 4. Turn on debug and collect data log at /var/tmp/tmon.log
106 $ sudo ./tmon -g -l                               106 $ sudo ./tmon -g -l
107                                                   107 
108 For example, the log below shows PID controlle    108 For example, the log below shows PID controller was adjusting current states
109 for all cooling devices with "Processor" type     109 for all cooling devices with "Processor" type such that thermal zone 0
110 can stay below 65 dC.                             110 can stay below 65 dC.
111                                                   111 
112 #---------- THERMAL DATA LOG STARTED ---------    112 #---------- THERMAL DATA LOG STARTED -----------
113 Samples TargetTemp acpitz0    acpitz1    Fan0     113 Samples TargetTemp acpitz0    acpitz1    Fan0 Fan1 Fan2 Fan3 Fan4 Fan5
114 Fan6 Fan7 Fan8 Fan9 Processor10 Processor11 Pr    114 Fan6 Fan7 Fan8 Fan9 Processor10 Processor11 Processor12 Processor13
115 LCD14 intel_powerclamp15 1 65.0 65 65 0 0 0 0     115 LCD14 intel_powerclamp15 1 65.0 65 65 0 0 0 0 0 0 0 0 0 0 0 0 0 0 6 0 2
116 65.0 66 65 0 0 0 0 0 0 0 0 0 0 4 4 4 4 6 0 3 6    116 65.0 66 65 0 0 0 0 0 0 0 0 0 0 4 4 4 4 6 0 3 65.0 60 54 0 0 0 0 0 0 0 0
117 0 0 4 4 4 4 6 0 4 65.0 53 53 0 0 0 0 0 0 0 0 0    117 0 0 4 4 4 4 6 0 4 65.0 53 53 0 0 0 0 0 0 0 0 0 0 4 4 4 4 6 0
118 5 65.0 52 52 0 0 0 0 0 0 0 0 0 0 0 0 0 0 6 0      118 5 65.0 52 52 0 0 0 0 0 0 0 0 0 0 0 0 0 0 6 0
119 6 65.0 53 65 0 0 0 0 0 0 0 0 0 0 0 0 0 0 6 0      119 6 65.0 53 65 0 0 0 0 0 0 0 0 0 0 0 0 0 0 6 0
120 7 65.0 68 70 0 0 0 0 0 0 0 0 0 0 0 0 0 0 6 0      120 7 65.0 68 70 0 0 0 0 0 0 0 0 0 0 0 0 0 0 6 0
121 8 65.0 68 68 0 0 0 0 0 0 0 0 0 0 5 5 5 5 6 0      121 8 65.0 68 68 0 0 0 0 0 0 0 0 0 0 5 5 5 5 6 0
122 9 65.0 68 68 0 0 0 0 0 0 0 0 0 0 6 6 6 6 6 0      122 9 65.0 68 68 0 0 0 0 0 0 0 0 0 0 6 6 6 6 6 0
123 10 65.0 67 67 0 0 0 0 0 0 0 0 0 0 7 7 7 7 6 0     123 10 65.0 67 67 0 0 0 0 0 0 0 0 0 0 7 7 7 7 6 0
124 11 65.0 67 67 0 0 0 0 0 0 0 0 0 0 8 8 8 8 6 0     124 11 65.0 67 67 0 0 0 0 0 0 0 0 0 0 8 8 8 8 6 0
125 12 65.0 67 67 0 0 0 0 0 0 0 0 0 0 8 8 8 8 6 0     125 12 65.0 67 67 0 0 0 0 0 0 0 0 0 0 8 8 8 8 6 0
126 13 65.0 67 67 0 0 0 0 0 0 0 0 0 0 9 9 9 9 6 0     126 13 65.0 67 67 0 0 0 0 0 0 0 0 0 0 9 9 9 9 6 0
127 14 65.0 66 66 0 0 0 0 0 0 0 0 0 0 10 10 10 10     127 14 65.0 66 66 0 0 0 0 0 0 0 0 0 0 10 10 10 10 6 0
128 15 65.0 66 67 0 0 0 0 0 0 0 0 0 0 10 10 10 10     128 15 65.0 66 67 0 0 0 0 0 0 0 0 0 0 10 10 10 10 6 0
129 16 65.0 66 66 0 0 0 0 0 0 0 0 0 0 11 11 11 11     129 16 65.0 66 66 0 0 0 0 0 0 0 0 0 0 11 11 11 11 6 0
130 17 65.0 66 66 0 0 0 0 0 0 0 0 0 0 11 11 11 11     130 17 65.0 66 66 0 0 0 0 0 0 0 0 0 0 11 11 11 11 6 0
131 18 65.0 64 61 0 0 0 0 0 0 0 0 0 0 11 11 11 11     131 18 65.0 64 61 0 0 0 0 0 0 0 0 0 0 11 11 11 11 6 0
132 19 65.0 60 59 0 0 0 0 0 0 0 0 0 0 12 12 12 12     132 19 65.0 60 59 0 0 0 0 0 0 0 0 0 0 12 12 12 12 6 0
133                                                   133 
134 Data can be read directly into an array by an     134 Data can be read directly into an array by an example R-script below:
135                                                   135 
136 #!/usr/bin/Rscript                                136 #!/usr/bin/Rscript
137 tdata <- read.table("/var/tmp/tmon.log", heade    137 tdata <- read.table("/var/tmp/tmon.log", header=T, comment.char="#")
138 attach(tdata)                                     138 attach(tdata)
139 jpeg("tmon.jpg")                                  139 jpeg("tmon.jpg")
140 X11()                                             140 X11()
141 g_range <- range(0, intel_powerclamp15, Target    141 g_range <- range(0, intel_powerclamp15, TargetTemp, acpitz0)
142 plot( Samples, intel_powerclamp15, col="blue",    142 plot( Samples, intel_powerclamp15, col="blue", ylim=g_range, axes=FALSE, ann=FALSE)
143 par(new=TRUE)                                     143 par(new=TRUE)
144 lines(TargetTemp, type="o", pch=22, lty=2, col    144 lines(TargetTemp, type="o", pch=22, lty=2, col="red")
145 dev.off()                                         145 dev.off()
                                                      

~ [ source navigation ] ~ [ diff markup ] ~ [ identifier search ] ~

kernel.org | git.kernel.org | LWN.net | Project Home | SVN repository | Mail admin

Linux® is a registered trademark of Linus Torvalds in the United States and other countries.
TOMOYO® is a registered trademark of NTT DATA CORPORATION.

sflogo.php