1 What: /sys/class/leds/<led>/flash_brightness 2 Date: March 2015 3 KernelVersion: 4.0 4 Contact: Jacek Anaszewski <j.anaszewski@samsung.com> 5 Description: read/write 6 Set the brightness of this LED in the flash strobe mode, in 7 microamperes. The file is created only for the flash LED devices 8 that support setting flash brightness. 9 10 The value is between 0 and 11 /sys/class/leds/<led>/max_flash_brightness. 12 13 What: /sys/class/leds/<led>/max_flash_brightness 14 Date: March 2015 15 KernelVersion: 4.0 16 Contact: Jacek Anaszewski <j.anaszewski@samsung.com> 17 Description: read only 18 Maximum brightness level for this LED in the flash strobe mode, 19 in microamperes. 20 21 What: /sys/class/leds/<led>/flash_timeout 22 Date: March 2015 23 KernelVersion: 4.0 24 Contact: Jacek Anaszewski <j.anaszewski@samsung.com> 25 Description: read/write 26 Hardware timeout for flash, in microseconds. The flash strobe 27 is stopped after this period of time has passed from the start 28 of the strobe. The file is created only for the flash LED 29 devices that support setting flash timeout. 30 31 What: /sys/class/leds/<led>/max_flash_timeout 32 Date: March 2015 33 KernelVersion: 4.0 34 Contact: Jacek Anaszewski <j.anaszewski@samsung.com> 35 Description: read only 36 Maximum flash timeout for this LED, in microseconds. 37 38 What: /sys/class/leds/<led>/flash_strobe 39 Date: March 2015 40 KernelVersion: 4.0 41 Contact: Jacek Anaszewski <j.anaszewski@samsung.com> 42 Description: read/write 43 Flash strobe state. When written with 1 it triggers flash strobe 44 and when written with 0 it turns the flash off. 45 46 On read 1 means that flash is currently strobing and 0 means 47 that flash is off. 48 49 What: /sys/class/leds/<led>/flash_fault 50 Date: March 2015 51 KernelVersion: 4.0 52 Contact: Jacek Anaszewski <j.anaszewski@samsung.com> 53 Description: read only 54 Space separated list of flash faults that may have occurred. 55 Flash faults are re-read after strobing the flash. Possible 56 flash faults: 57 58 * led-over-voltage 59 flash controller voltage to the flash LED 60 has exceeded the limit specific to the flash controller 61 * flash-timeout-exceeded 62 the flash strobe was still on when 63 the timeout set by the user has expired; not all flash 64 controllers may set this in all such conditions 65 * controller-over-temperature 66 the flash controller has 67 overheated 68 * controller-short-circuit 69 the short circuit protection 70 of the flash controller has been triggered 71 * led-power-supply-over-current 72 current in the LED power 73 supply has exceeded the limit specific to the flash 74 controller 75 * indicator-led-fault 76 the flash controller has detected 77 a short or open circuit condition on the indicator LED 78 * led-under-voltage 79 flash controller voltage to the flash 80 LED has been below the minimum limit specific to 81 the flash 82 * controller-under-voltage 83 the input voltage of the flash 84 controller is below the limit under which strobing the 85 flash at full current will not be possible; 86 the condition persists until this flag is no longer set 87 * led-over-temperature 88 the temperature of the LED has exceeded 89 its allowed upper limit
Linux® is a registered trademark of Linus Torvalds in the United States and other countries.
TOMOYO® is a registered trademark of NTT DATA CORPORATION.