Version: ~ [ linux-6.12-rc7 ] ~ [ linux-6.11.7 ] ~ [ linux-6.10.14 ] ~ [ linux-6.9.12 ] ~ [ linux-6.8.12 ] ~ [ linux-6.7.12 ] ~ [ linux-6.6.60 ] ~ [ linux-6.5.13 ] ~ [ linux-6.4.16 ] ~ [ linux-6.3.13 ] ~ [ linux-6.2.16 ] ~ [ linux-6.1.116 ] ~ [ linux-6.0.19 ] ~ [ linux-5.19.17 ] ~ [ linux-5.18.19 ] ~ [ linux-5.17.15 ] ~ [ linux-5.16.20 ] ~ [ linux-5.15.171 ] ~ [ linux-5.14.21 ] ~ [ linux-5.13.19 ] ~ [ linux-5.12.19 ] ~ [ linux-5.11.22 ] ~ [ linux-5.10.229 ] ~ [ linux-5.9.16 ] ~ [ linux-5.8.18 ] ~ [ linux-5.7.19 ] ~ [ linux-5.6.19 ] ~ [ linux-5.5.19 ] ~ [ linux-5.4.285 ] ~ [ linux-5.3.18 ] ~ [ linux-5.2.21 ] ~ [ linux-5.1.21 ] ~ [ linux-5.0.21 ] ~ [ linux-4.20.17 ] ~ [ linux-4.19.323 ] ~ [ linux-4.18.20 ] ~ [ linux-4.17.19 ] ~ [ linux-4.16.18 ] ~ [ linux-4.15.18 ] ~ [ linux-4.14.336 ] ~ [ linux-4.13.16 ] ~ [ linux-4.12.14 ] ~ [ linux-4.11.12 ] ~ [ linux-4.10.17 ] ~ [ linux-4.9.337 ] ~ [ linux-4.4.302 ] ~ [ linux-3.10.108 ] ~ [ linux-2.6.32.71 ] ~ [ linux-2.6.0 ] ~ [ linux-2.4.37.11 ] ~ [ unix-v6-master ] ~ [ ccs-tools-1.8.12 ] ~ [ policy-sample ] ~
Architecture: ~ [ i386 ] ~ [ alpha ] ~ [ m68k ] ~ [ mips ] ~ [ ppc ] ~ [ sparc ] ~ [ sparc64 ] ~

  1 What:           /sys/firmware/sgi_uv/
  2 Date:           September 2020
  3 Contact:        Justin Ernst <justin.ernst@hpe.com>
  4 Description:
  5                 The /sys/firmware/sgi_uv directory contains information
  6                 about the UV platform.
  7 
  8                 Under that directory are a number of read-only attributes::
  9 
 10                         archtype
 11                         hub_type
 12                         hubless
 13                         partition_id
 14                         coherence_id
 15                         uv_type
 16 
 17                 The archtype entry contains the UV architecture type that
 18                 is used to select arch-dependent addresses and features.
 19                 It can be set via the OEM_ID in the ACPI MADT table or by
 20                 UVsystab entry both passed from UV BIOS.
 21 
 22                 The hub_type entry is used to select the type of hub which is
 23                 similar to uv_type but encoded in a binary format.  Include
 24                 the file uv_hub.h to get the definitions.
 25 
 26                 The hubless entry basically is present and set only if there
 27                 is no hub.  In this case the hub_type entry is not present.
 28 
 29                 The partition_id entry contains the partition id.
 30                 UV systems can be partitioned into multiple physical
 31                 machines, which each partition running a unique copy
 32                 of the operating system. Each partition will have a unique
 33                 partition id.
 34 
 35                 The coherence_id entry contains the coherence id.
 36                 A partitioned UV system can have one or more coherence
 37                 domains. The coherence id indicates which coherence domain
 38                 this partition is in.
 39 
 40                 The uv_type entry contains the hub revision number.
 41                 This value can be used to identify the UV system version::
 42 
 43                         "0.*" = Hubless UV ('*' is subtype)
 44                         "3.0" = UV2
 45                         "5.0" = UV3
 46                         "7.0" = UV4
 47                         "7.1" = UV4a
 48                         "9.0" = UV5
 49 
 50                 The /sys/firmware/sgi_uv directory also contains two directories::
 51 
 52                         hubs/
 53                         pcibuses/
 54 
 55                 The hubs directory contains a number of hub objects, each representing
 56                 a UV Hub visible to the BIOS. Each hub object's name is appended by a
 57                 unique ordinal value (ex. /sys/firmware/sgi_uv/hubs/hub_5)
 58 
 59                 Each hub object directory contains a number of read-only attributes::
 60 
 61                         cnode
 62                         location
 63                         name
 64                         nasid
 65                         shared
 66                         this_partition
 67 
 68                 The cnode entry contains the cnode number of the corresponding hub.
 69                 If a cnode value is not applicable, the value returned will be -1.
 70 
 71                 The location entry contains the location string of the corresponding hub.
 72                 This value is used to physically identify a hub within a system.
 73 
 74                 The name entry contains the name of the corresponding hub. This name can
 75                 be two variants::
 76 
 77                         "UVHub x.x" = A 'node' ASIC, connecting a CPU to the interconnect
 78                         fabric. The 'x.x' value represents the ASIC revision.
 79                         (ex. 'UVHub 5.0')
 80 
 81                         "NLxRouter" = A 'router ASIC, only connecting other ASICs to
 82                         the interconnect fabric. The 'x' value representing
 83                         the fabric technology version. (ex. 'NL8Router')
 84 
 85                 The nasid entry contains the nasid number of the corresponding hub.
 86                 If a nasid value is not applicable, the value returned will be -1.
 87 
 88                 The shared entry contains a boolean value describing whether the
 89                 corresponding hub is shared between system partitions.
 90 
 91                 The this_partition entry contains a boolean value describing whether
 92                 the corresponding hub is local to the current partition.
 93 
 94                 Each hub object directory also contains a number of port objects,
 95                 each representing a fabric port on the corresponding hub.
 96                 A port object's name is appended by a unique ordinal value
 97                 (ex. /sys/firmware/sgi_uv/hubs/hub_5/port_3)
 98 
 99                 Each port object directory contains a number of read-only attributes::
100 
101                         conn_hub
102                         conn_port
103 
104                 The conn_hub entry contains a value representing the unique
105                 ordinal value of the hub on the other end of the fabric
106                 cable plugged into the port. If the port is disconnected,
107                 the value returned will be -1.
108 
109                 The conn_port entry contains a value representing the unique
110                 ordinal value of the port on the other end of the fabric cable
111                 plugged into the port. If the port is disconnected, the value
112                 returned will be -1.
113 
114                 Ex:
115                         A value of '3' is read from:
116                                 /sys/firmware/sgi_uv/hubs/hub_5/port_3/conn_hub
117 
118                         and a value of '6' is read from:
119                                 /sys/firmware/sgi_uv/hubs/hub_5/port_3/conn_port
120 
121                         representing that this port is connected to:
122                                 /sys/firmware/sgi_uv/hubs/hub_3/port_6
123 
124                 The pcibuses directory contains a number of PCI bus objects.
125                 Each PCI bus object's name is appended by its PCI bus address.
126                 (ex. pcibus_0003:80)
127 
128                 Each pcibus object has a number of possible read-only attributes::
129 
130                         type
131                         location
132                         slot
133                         ppb_addr
134                         iio_stack
135 
136                 The type entry contains a value describing the type of IO at
137                 the corresponding PCI bus address. Known possible values
138                 across all UV versions are::
139 
140                         BASE IO
141                         PCIe IO
142                         PCIe SLOT
143                         NODE IO
144                         Riser
145                         PPB
146 
147                 The location entry contains the location string of the UV Hub
148                 of the CPU physically connected to the corresponding PCI bus.
149 
150                 The slot entry contains the physical slot number of the
151                 corresponding PCI bus. This value is used to physically locate
152                 PCI cards within a system.
153 
154                 The ppb_addr entry contains the PCI address string of the
155                 bridged PCI bus. This entry is only present when the PCI bus
156                 object type is 'PPB'.
157 
158                 The iio_stack entry contains a value describing the IIO stack
159                 number that the corresponding PCI bus object is connected to.

~ [ source navigation ] ~ [ diff markup ] ~ [ identifier search ] ~

kernel.org | git.kernel.org | LWN.net | Project Home | SVN repository | Mail admin

Linux® is a registered trademark of Linus Torvalds in the United States and other countries.
TOMOYO® is a registered trademark of NTT DATA CORPORATION.

sflogo.php