1 * ARC Performance Counters 2 3 The ARC700 can be configured with a pipeline performance monitor for counting 4 CPU and cache events like cache misses and hits. Like conventional PCT there 5 are 100+ hardware conditions dynamically mapped to up to 32 counters 6 7 Note that: 8 * The ARC 700 PCT does not support interrupts; although HW events may be 9 counted, the HW events themselves cannot serve as a trigger for a sample. 10 11 Required properties: 12 13 - compatible : should contain 14 "snps,arc700-pct" 15 16 Example: 17 18 pmu { 19 compatible = "snps,arc700-pct"; 20 };
Linux® is a registered trademark of Linus Torvalds in the United States and other countries.
TOMOYO® is a registered trademark of NTT DATA CORPORATION.