1 # SPDX-License-Identifier: GPL-2.0 2 %YAML 1.2 3 --- 4 $id: http://devicetree.org/schemas/interconnect/samsung,exynos-bus.yaml# 5 $schema: http://devicetree.org/meta-schemas/core.yaml# 6 7 title: Samsung Exynos SoC Bus and Interconnect 8 9 maintainers: 10 - Chanwoo Choi <cw00.choi@samsung.com> 11 - Krzysztof Kozlowski <krzk@kernel.org> 12 13 description: | 14 The Samsung Exynos SoC has many buses for data transfer between DRAM and 15 sub-blocks in SoC. Most Exynos SoCs share the common architecture for buses. 16 Generally, each bus of Exynos SoC includes a source clock and a power line, 17 which are able to change the clock frequency of the bus in runtime. To 18 monitor the usage of each bus in runtime, the driver uses the PPMU (Platform 19 Performance Monitoring Unit), which is able to measure the current load of 20 sub-blocks. 21 22 The Exynos SoC includes the various sub-blocks which have the each AXI bus. 23 The each AXI bus has the owned source clock but, has not the only owned power 24 line. The power line might be shared among one more sub-blocks. So, we can 25 divide into two type of device as the role of each sub-block. There are two 26 type of bus devices as following:: 27 - parent bus device 28 - passive bus device 29 30 Basically, parent and passive bus device share the same power line. The 31 parent bus device can only change the voltage of shared power line and the 32 rest bus devices (passive bus device) depend on the decision of the parent 33 bus device. If there are three blocks which share the VDD_xxx power line, 34 Only one block should be parent device and then the rest blocks should depend 35 on the parent device as passive device. 36 37 VDD_xxx |--- A block (parent) 38 |--- B block (passive) 39 |--- C block (passive) 40 41 There are a little different composition among Exynos SoC because each Exynos 42 SoC has different sub-blocks. Therefore, such difference should be specified 43 in devicetree file instead of each device driver. In result, this driver is 44 able to support the bus frequency for all Exynos SoCs. 45 46 Detailed correlation between sub-blocks and power line according 47 to Exynos SoC:: 48 - In case of Exynos3250, there are two power line as following:: 49 VDD_MIF |--- DMC (Dynamic Memory Controller) 50 51 VDD_INT |--- LEFTBUS (parent device) 52 |--- PERIL 53 |--- MFC 54 |--- G3D 55 |--- RIGHTBUS 56 |--- PERIR 57 |--- FSYS 58 |--- LCD0 59 |--- PERIR 60 |--- ISP 61 |--- CAM 62 63 - MIF bus's frequency/voltage table 64 ----------------------- 65 |Lv| Freq | Voltage | 66 ----------------------- 67 |L1| 50000 |800000 | 68 |L2| 100000 |800000 | 69 |L3| 134000 |800000 | 70 |L4| 200000 |825000 | 71 |L5| 400000 |875000 | 72 ----------------------- 73 74 - INT bus's frequency/voltage table 75 ---------------------------------------------------------- 76 |Block|LEFTBUS|RIGHTBUS|MCUISP |ISP |PERIL ||VDD_INT | 77 | name| |LCD0 | | | || | 78 | | |FSYS | | | || | 79 | | |MFC | | | || | 80 ---------------------------------------------------------- 81 |Mode |*parent|passive |passive|passive|passive|| | 82 ---------------------------------------------------------- 83 |Lv |Frequency ||Voltage | 84 ---------------------------------------------------------- 85 |L1 |50000 |50000 |50000 |50000 |50000 ||900000 | 86 |L2 |80000 |80000 |80000 |80000 |80000 ||900000 | 87 |L3 |100000 |100000 |100000 |100000 |100000 ||1000000 | 88 |L4 |134000 |134000 |200000 |200000 | ||1000000 | 89 |L5 |200000 |200000 |400000 |300000 | ||1000000 | 90 ---------------------------------------------------------- 91 92 - In case of Exynos4210, there is one power line as following:: 93 VDD_INT |--- DMC (parent device, Dynamic Memory Controller) 94 |--- LEFTBUS 95 |--- PERIL 96 |--- MFC(L) 97 |--- G3D 98 |--- TV 99 |--- LCD0 100 |--- RIGHTBUS 101 |--- PERIR 102 |--- MFC(R) 103 |--- CAM 104 |--- FSYS 105 |--- GPS 106 |--- LCD0 107 |--- LCD1 108 109 - In case of Exynos4x12, there are two power line as following:: 110 VDD_MIF |--- DMC (Dynamic Memory Controller) 111 112 VDD_INT |--- LEFTBUS (parent device) 113 |--- PERIL 114 |--- MFC(L) 115 |--- G3D 116 |--- TV 117 |--- IMAGE 118 |--- RIGHTBUS 119 |--- PERIR 120 |--- MFC(R) 121 |--- CAM 122 |--- FSYS 123 |--- GPS 124 |--- LCD0 125 |--- ISP 126 127 - In case of Exynos5422, there are two power line as following:: 128 VDD_MIF |--- DREX 0 (parent device, DRAM EXpress controller) 129 |--- DREX 1 130 131 VDD_INT |--- NoC_Core (parent device) 132 |--- G2D 133 |--- G3D 134 |--- DISP1 135 |--- NoC_WCORE 136 |--- GSCL 137 |--- MSCL 138 |--- ISP 139 |--- MFC 140 |--- GEN 141 |--- PERIS 142 |--- PERIC 143 |--- FSYS 144 |--- FSYS2 145 146 - In case of Exynos5433, there is VDD_INT power line as following:: 147 VDD_INT |--- G2D (parent device) 148 |--- MSCL 149 |--- GSCL 150 |--- JPEG 151 |--- MFC 152 |--- HEVC 153 |--- BUS0 154 |--- BUS1 155 |--- BUS2 156 |--- PERIS (Fixed clock rate) 157 |--- PERIC (Fixed clock rate) 158 |--- FSYS (Fixed clock rate) 159 160 properties: 161 compatible: 162 enum: 163 - samsung,exynos-bus 164 165 clocks: 166 maxItems: 1 167 168 clock-names: 169 items: 170 - const: bus 171 172 devfreq: 173 $ref: /schemas/types.yaml#/definitions/phandle 174 description: 175 Parent bus device. Valid and required only for the passive bus devices. 176 177 devfreq-events: 178 $ref: /schemas/types.yaml#/definitions/phandle-array 179 minItems: 1 180 maxItems: 4 181 description: 182 Devfreq-event device to monitor the current utilization of buses. Valid 183 and required only for the parent bus devices. 184 185 exynos,saturation-ratio: 186 $ref: /schemas/types.yaml#/definitions/uint32 187 description: 188 Percentage value which is used to calibrate the performance count against 189 total cycle count. Valid only for the parent bus devices. 190 191 '#interconnect-cells': 192 const: 0 193 194 interconnects: 195 minItems: 1 196 maxItems: 2 197 198 operating-points-v2: true 199 opp-table: 200 type: object 201 202 samsung,data-clock-ratio: 203 $ref: /schemas/types.yaml#/definitions/uint32 204 default: 8 205 description: 206 Ratio of the data throughput in B/s to minimum data clock frequency in 207 Hz. 208 209 vdd-supply: 210 description: 211 Main bus power rail. Valid and required only for the parent bus devices. 212 213 required: 214 - compatible 215 - clocks 216 - clock-names 217 - operating-points-v2 218 219 additionalProperties: false 220 221 examples: 222 - | 223 #include <dt-bindings/clock/exynos3250.h> 224 225 bus-dmc { 226 compatible = "samsung,exynos-bus"; 227 clocks = <&cmu_dmc CLK_DIV_DMC>; 228 clock-names = "bus"; 229 operating-points-v2 = <&bus_dmc_opp_table>; 230 devfreq-events = <&ppmu_dmc0_3>, <&ppmu_dmc1_3>; 231 vdd-supply = <&buck1_reg>; 232 233 bus_dmc_opp_table: opp-table { 234 compatible = "operating-points-v2"; 235 236 opp-50000000 { 237 opp-hz = /bits/ 64 <50000000>; 238 opp-microvolt = <800000>; 239 }; 240 opp-100000000 { 241 opp-hz = /bits/ 64 <100000000>; 242 opp-microvolt = <800000>; 243 }; 244 opp-134000000 { 245 opp-hz = /bits/ 64 <134000000>; 246 opp-microvolt = <800000>; 247 }; 248 opp-200000000 { 249 opp-hz = /bits/ 64 <200000000>; 250 opp-microvolt = <825000>; 251 }; 252 opp-400000000 { 253 opp-hz = /bits/ 64 <400000000>; 254 opp-microvolt = <875000>; 255 }; 256 }; 257 }; 258 259 ppmu_dmc0: ppmu@106a0000 { 260 compatible = "samsung,exynos-ppmu"; 261 reg = <0x106a0000 0x2000>; 262 events { 263 ppmu_dmc0_3: ppmu-event3-dmc0 { 264 event-name = "ppmu-event3-dmc0"; 265 }; 266 }; 267 }; 268 269 bus_leftbus: bus-leftbus { 270 compatible = "samsung,exynos-bus"; 271 clocks = <&cmu CLK_DIV_GDL>; 272 clock-names = "bus"; 273 operating-points-v2 = <&bus_leftbus_opp_table>; 274 devfreq-events = <&ppmu_leftbus_3>, <&ppmu_rightbus_3>; 275 vdd-supply = <&buck3_reg>; 276 }; 277 278 bus-rightbus { 279 compatible = "samsung,exynos-bus"; 280 clocks = <&cmu CLK_DIV_GDR>; 281 clock-names = "bus"; 282 operating-points-v2 = <&bus_leftbus_opp_table>; 283 devfreq = <&bus_leftbus>; 284 }; 285 286 - | 287 dmc: bus-dmc { 288 compatible = "samsung,exynos-bus"; 289 clocks = <&clock CLK_DIV_DMC>; 290 clock-names = "bus"; 291 operating-points-v2 = <&bus_dmc_opp_table>; 292 samsung,data-clock-ratio = <4>; 293 #interconnect-cells = <0>; 294 devfreq-events = <&ppmu_dmc0_3>, <&ppmu_dmc1_3>; 295 vdd-supply = <&buck1_reg>; 296 }; 297 298 leftbus: bus-leftbus { 299 compatible = "samsung,exynos-bus"; 300 clocks = <&clock CLK_DIV_GDL>; 301 clock-names = "bus"; 302 operating-points-v2 = <&bus_leftbus_opp_table>; 303 interconnects = <&dmc>; 304 #interconnect-cells = <0>; 305 devfreq-events = <&ppmu_leftbus_3>, <&ppmu_rightbus_3>; 306 vdd-supply = <&buck3_reg>; 307 }; 308 309 display: bus-display { 310 compatible = "samsung,exynos-bus"; 311 clocks = <&clock CLK_DIV_ACLK_266>; 312 clock-names = "bus"; 313 operating-points-v2 = <&bus_display_opp_table>; 314 interconnects = <&leftbus &dmc>; 315 #interconnect-cells = <0>; 316 devfreq = <&leftbus>; 317 };
Linux® is a registered trademark of Linus Torvalds in the United States and other countries.
TOMOYO® is a registered trademark of NTT DATA CORPORATION.