Version: ~ [ linux-6.12-rc7 ] ~ [ linux-6.11.7 ] ~ [ linux-6.10.14 ] ~ [ linux-6.9.12 ] ~ [ linux-6.8.12 ] ~ [ linux-6.7.12 ] ~ [ linux-6.6.60 ] ~ [ linux-6.5.13 ] ~ [ linux-6.4.16 ] ~ [ linux-6.3.13 ] ~ [ linux-6.2.16 ] ~ [ linux-6.1.116 ] ~ [ linux-6.0.19 ] ~ [ linux-5.19.17 ] ~ [ linux-5.18.19 ] ~ [ linux-5.17.15 ] ~ [ linux-5.16.20 ] ~ [ linux-5.15.171 ] ~ [ linux-5.14.21 ] ~ [ linux-5.13.19 ] ~ [ linux-5.12.19 ] ~ [ linux-5.11.22 ] ~ [ linux-5.10.229 ] ~ [ linux-5.9.16 ] ~ [ linux-5.8.18 ] ~ [ linux-5.7.19 ] ~ [ linux-5.6.19 ] ~ [ linux-5.5.19 ] ~ [ linux-5.4.285 ] ~ [ linux-5.3.18 ] ~ [ linux-5.2.21 ] ~ [ linux-5.1.21 ] ~ [ linux-5.0.21 ] ~ [ linux-4.20.17 ] ~ [ linux-4.19.323 ] ~ [ linux-4.18.20 ] ~ [ linux-4.17.19 ] ~ [ linux-4.16.18 ] ~ [ linux-4.15.18 ] ~ [ linux-4.14.336 ] ~ [ linux-4.13.16 ] ~ [ linux-4.12.14 ] ~ [ linux-4.11.12 ] ~ [ linux-4.10.17 ] ~ [ linux-4.9.337 ] ~ [ linux-4.4.302 ] ~ [ linux-3.10.108 ] ~ [ linux-2.6.32.71 ] ~ [ linux-2.6.0 ] ~ [ linux-2.4.37.11 ] ~ [ unix-v6-master ] ~ [ ccs-tools-1.8.12 ] ~ [ policy-sample ] ~
Architecture: ~ [ i386 ] ~ [ alpha ] ~ [ m68k ] ~ [ mips ] ~ [ ppc ] ~ [ sparc ] ~ [ sparc64 ] ~

  1 # SPDX-License-Identifier: GPL-2.0
  2 %YAML 1.2
  3 ---
  4 $id: http://devicetree.org/schemas/interconnect/samsung,exynos-bus.yaml#
  5 $schema: http://devicetree.org/meta-schemas/core.yaml#
  6 
  7 title: Samsung Exynos SoC Bus and Interconnect
  8 
  9 maintainers:
 10   - Chanwoo Choi <cw00.choi@samsung.com>
 11   - Krzysztof Kozlowski <krzk@kernel.org>
 12 
 13 description: |
 14   The Samsung Exynos SoC has many buses for data transfer between DRAM and
 15   sub-blocks in SoC. Most Exynos SoCs share the common architecture for buses.
 16   Generally, each bus of Exynos SoC includes a source clock and a power line,
 17   which are able to change the clock frequency of the bus in runtime. To
 18   monitor the usage of each bus in runtime, the driver uses the PPMU (Platform
 19   Performance Monitoring Unit), which is able to measure the current load of
 20   sub-blocks.
 21 
 22   The Exynos SoC includes the various sub-blocks which have the each AXI bus.
 23   The each AXI bus has the owned source clock but, has not the only owned power
 24   line. The power line might be shared among one more sub-blocks.  So, we can
 25   divide into two type of device as the role of each sub-block.  There are two
 26   type of bus devices as following::
 27    - parent bus device
 28    - passive bus device
 29 
 30   Basically, parent and passive bus device share the same power line.  The
 31   parent bus device can only change the voltage of shared power line and the
 32   rest bus devices (passive bus device) depend on the decision of the parent
 33   bus device. If there are three blocks which share the VDD_xxx power line,
 34   Only one block should be parent device and then the rest blocks should depend
 35   on the parent device as passive device.
 36 
 37     VDD_xxx |--- A block (parent)
 38       |--- B block (passive)
 39       |--- C block (passive)
 40 
 41   There are a little different composition among Exynos SoC because each Exynos
 42   SoC has different sub-blocks. Therefore, such difference should be specified
 43   in devicetree file instead of each device driver. In result, this driver is
 44   able to support the bus frequency for all Exynos SoCs.
 45 
 46   Detailed correlation between sub-blocks and power line according
 47   to Exynos SoC::
 48    - In case of Exynos3250, there are two power line as following::
 49      VDD_MIF |--- DMC (Dynamic Memory Controller)
 50 
 51      VDD_INT |--- LEFTBUS (parent device)
 52        |--- PERIL
 53        |--- MFC
 54        |--- G3D
 55        |--- RIGHTBUS
 56        |--- PERIR
 57        |--- FSYS
 58        |--- LCD0
 59        |--- PERIR
 60        |--- ISP
 61        |--- CAM
 62 
 63      - MIF bus's frequency/voltage table
 64        -----------------------
 65        |Lv| Freq   | Voltage |
 66        -----------------------
 67        |L1| 50000  |800000   |
 68        |L2| 100000 |800000   |
 69        |L3| 134000 |800000   |
 70        |L4| 200000 |825000   |
 71        |L5| 400000 |875000   |
 72        -----------------------
 73 
 74      - INT bus's frequency/voltage table
 75        ----------------------------------------------------------
 76        |Block|LEFTBUS|RIGHTBUS|MCUISP |ISP    |PERIL  ||VDD_INT |
 77        | name|       |LCD0    |       |       |       ||        |
 78        |     |       |FSYS    |       |       |       ||        |
 79        |     |       |MFC     |       |       |       ||        |
 80        ----------------------------------------------------------
 81        |Mode |*parent|passive |passive|passive|passive||        |
 82        ----------------------------------------------------------
 83        |Lv   |Frequency                               ||Voltage |
 84        ----------------------------------------------------------
 85        |L1   |50000  |50000   |50000  |50000  |50000  ||900000  |
 86        |L2   |80000  |80000   |80000  |80000  |80000  ||900000  |
 87        |L3   |100000 |100000  |100000 |100000 |100000 ||1000000 |
 88        |L4   |134000 |134000  |200000 |200000 |       ||1000000 |
 89        |L5   |200000 |200000  |400000 |300000 |       ||1000000 |
 90        ----------------------------------------------------------
 91 
 92    - In case of Exynos4210, there is one power line as following::
 93      VDD_INT |--- DMC (parent device, Dynamic Memory Controller)
 94        |--- LEFTBUS
 95        |--- PERIL
 96        |--- MFC(L)
 97        |--- G3D
 98        |--- TV
 99        |--- LCD0
100        |--- RIGHTBUS
101        |--- PERIR
102        |--- MFC(R)
103        |--- CAM
104        |--- FSYS
105        |--- GPS
106        |--- LCD0
107        |--- LCD1
108 
109    - In case of Exynos4x12, there are two power line as following::
110      VDD_MIF |--- DMC (Dynamic Memory Controller)
111 
112      VDD_INT |--- LEFTBUS (parent device)
113        |--- PERIL
114        |--- MFC(L)
115        |--- G3D
116        |--- TV
117        |--- IMAGE
118        |--- RIGHTBUS
119        |--- PERIR
120        |--- MFC(R)
121        |--- CAM
122        |--- FSYS
123        |--- GPS
124        |--- LCD0
125        |--- ISP
126 
127    - In case of Exynos5422, there are two power line as following::
128      VDD_MIF |--- DREX 0 (parent device, DRAM EXpress controller)
129              |--- DREX 1
130 
131      VDD_INT |--- NoC_Core (parent device)
132        |--- G2D
133        |--- G3D
134        |--- DISP1
135        |--- NoC_WCORE
136        |--- GSCL
137        |--- MSCL
138        |--- ISP
139        |--- MFC
140        |--- GEN
141        |--- PERIS
142        |--- PERIC
143        |--- FSYS
144        |--- FSYS2
145 
146    - In case of Exynos5433, there is VDD_INT power line as following::
147      VDD_INT |--- G2D (parent device)
148        |--- MSCL
149        |--- GSCL
150        |--- JPEG
151        |--- MFC
152        |--- HEVC
153        |--- BUS0
154        |--- BUS1
155        |--- BUS2
156        |--- PERIS (Fixed clock rate)
157        |--- PERIC (Fixed clock rate)
158        |--- FSYS  (Fixed clock rate)
159 
160 properties:
161   compatible:
162     enum:
163       - samsung,exynos-bus
164 
165   clocks:
166     maxItems: 1
167 
168   clock-names:
169     items:
170       - const: bus
171 
172   devfreq:
173     $ref: /schemas/types.yaml#/definitions/phandle
174     description:
175       Parent bus device. Valid and required only for the passive bus devices.
176 
177   devfreq-events:
178     $ref: /schemas/types.yaml#/definitions/phandle-array
179     minItems: 1
180     maxItems: 4
181     description:
182       Devfreq-event device to monitor the current utilization of buses. Valid
183       and required only for the parent bus devices.
184 
185   exynos,saturation-ratio:
186     $ref: /schemas/types.yaml#/definitions/uint32
187     description:
188       Percentage value which is used to calibrate the performance count against
189       total cycle count.  Valid only for the parent bus devices.
190 
191   '#interconnect-cells':
192     const: 0
193 
194   interconnects:
195     minItems: 1
196     maxItems: 2
197 
198   operating-points-v2: true
199   opp-table:
200     type: object
201 
202   samsung,data-clock-ratio:
203     $ref: /schemas/types.yaml#/definitions/uint32
204     default: 8
205     description:
206       Ratio of the data throughput in B/s to minimum data clock frequency in
207       Hz.
208 
209   vdd-supply:
210     description:
211       Main bus power rail. Valid and required only for the parent bus devices.
212 
213 required:
214   - compatible
215   - clocks
216   - clock-names
217   - operating-points-v2
218 
219 additionalProperties: false
220 
221 examples:
222   - |
223     #include <dt-bindings/clock/exynos3250.h>
224 
225     bus-dmc {
226         compatible = "samsung,exynos-bus";
227         clocks = <&cmu_dmc CLK_DIV_DMC>;
228         clock-names = "bus";
229         operating-points-v2 = <&bus_dmc_opp_table>;
230         devfreq-events = <&ppmu_dmc0_3>, <&ppmu_dmc1_3>;
231         vdd-supply = <&buck1_reg>;
232 
233         bus_dmc_opp_table: opp-table {
234             compatible = "operating-points-v2";
235 
236             opp-50000000 {
237                 opp-hz = /bits/ 64 <50000000>;
238                 opp-microvolt = <800000>;
239             };
240             opp-100000000 {
241                 opp-hz = /bits/ 64 <100000000>;
242                 opp-microvolt = <800000>;
243             };
244             opp-134000000 {
245                 opp-hz = /bits/ 64 <134000000>;
246                 opp-microvolt = <800000>;
247             };
248             opp-200000000 {
249                 opp-hz = /bits/ 64 <200000000>;
250                 opp-microvolt = <825000>;
251             };
252             opp-400000000 {
253                 opp-hz = /bits/ 64 <400000000>;
254                 opp-microvolt = <875000>;
255             };
256         };
257     };
258 
259     ppmu_dmc0: ppmu@106a0000 {
260         compatible = "samsung,exynos-ppmu";
261         reg = <0x106a0000 0x2000>;
262         events {
263             ppmu_dmc0_3: ppmu-event3-dmc0 {
264                 event-name = "ppmu-event3-dmc0";
265             };
266         };
267     };
268 
269     bus_leftbus: bus-leftbus {
270         compatible = "samsung,exynos-bus";
271         clocks = <&cmu CLK_DIV_GDL>;
272         clock-names = "bus";
273         operating-points-v2 = <&bus_leftbus_opp_table>;
274         devfreq-events = <&ppmu_leftbus_3>, <&ppmu_rightbus_3>;
275         vdd-supply = <&buck3_reg>;
276     };
277 
278     bus-rightbus {
279         compatible = "samsung,exynos-bus";
280         clocks = <&cmu CLK_DIV_GDR>;
281         clock-names = "bus";
282         operating-points-v2 = <&bus_leftbus_opp_table>;
283         devfreq = <&bus_leftbus>;
284     };
285 
286   - |
287     dmc: bus-dmc {
288         compatible = "samsung,exynos-bus";
289         clocks = <&clock CLK_DIV_DMC>;
290         clock-names = "bus";
291         operating-points-v2 = <&bus_dmc_opp_table>;
292         samsung,data-clock-ratio = <4>;
293         #interconnect-cells = <0>;
294         devfreq-events = <&ppmu_dmc0_3>, <&ppmu_dmc1_3>;
295         vdd-supply = <&buck1_reg>;
296     };
297 
298     leftbus: bus-leftbus {
299         compatible = "samsung,exynos-bus";
300         clocks = <&clock CLK_DIV_GDL>;
301         clock-names = "bus";
302         operating-points-v2 = <&bus_leftbus_opp_table>;
303         interconnects = <&dmc>;
304         #interconnect-cells = <0>;
305         devfreq-events = <&ppmu_leftbus_3>, <&ppmu_rightbus_3>;
306         vdd-supply = <&buck3_reg>;
307     };
308 
309     display: bus-display {
310         compatible = "samsung,exynos-bus";
311         clocks = <&clock CLK_DIV_ACLK_266>;
312         clock-names = "bus";
313         operating-points-v2 = <&bus_display_opp_table>;
314         interconnects = <&leftbus &dmc>;
315         #interconnect-cells = <0>;
316         devfreq = <&leftbus>;
317     };

~ [ source navigation ] ~ [ diff markup ] ~ [ identifier search ] ~