1 Cirrus Logic CLPS711X Interrupt Controller 2 3 Required properties: 4 5 - compatible: Should be "cirrus,ep7209-intc". 6 - reg: Specifies base physical address of the registers set. 7 - interrupt-controller: Identifies the node as an interrupt controller. 8 - #interrupt-cells: Specifies the number of cells needed to encode an 9 interrupt source. The value shall be 1. 10 11 The interrupt sources are as follows: 12 ID Name Description 13 --------------------------- 14 1: BLINT Battery low (FIQ) 15 3: MCINT Media changed (FIQ) 16 4: CSINT CODEC sound 17 5: EINT1 External 1 18 6: EINT2 External 2 19 7: EINT3 External 3 20 8: TC1OI TC1 under flow 21 9: TC2OI TC2 under flow 22 10: RTCMI RTC compare match 23 11: TINT 64Hz tick 24 12: UTXINT1 UART1 transmit FIFO half empty 25 13: URXINT1 UART1 receive FIFO half full 26 14: UMSINT UART1 modem status changed 27 15: SSEOTI SSI1 end of transfer 28 16: KBDINT Keyboard 29 17: SS2RX SSI2 receive FIFO half or greater full 30 18: SS2TX SSI2 transmit FIFO less than half empty 31 28: UTXINT2 UART2 transmit FIFO half empty 32 29: URXINT2 UART2 receive FIFO half full 33 32: DAIINT DAI interface (FIQ) 34 35 Example: 36 intc: interrupt-controller { 37 compatible = "cirrus,ep7312-intc", "cirrus,ep7209-intc"; 38 reg = <0x80000000 0x4000>; 39 interrupt-controller; 40 #interrupt-cells = <1>; 41 };
Linux® is a registered trademark of Linus Torvalds in the United States and other countries.
TOMOYO® is a registered trademark of NTT DATA CORPORATION.