Version: ~ [ linux-6.11.5 ] ~ [ linux-6.10.14 ] ~ [ linux-6.9.12 ] ~ [ linux-6.8.12 ] ~ [ linux-6.7.12 ] ~ [ linux-6.6.58 ] ~ [ linux-6.5.13 ] ~ [ linux-6.4.16 ] ~ [ linux-6.3.13 ] ~ [ linux-6.2.16 ] ~ [ linux-6.1.114 ] ~ [ linux-6.0.19 ] ~ [ linux-5.19.17 ] ~ [ linux-5.18.19 ] ~ [ linux-5.17.15 ] ~ [ linux-5.16.20 ] ~ [ linux-5.15.169 ] ~ [ linux-5.14.21 ] ~ [ linux-5.13.19 ] ~ [ linux-5.12.19 ] ~ [ linux-5.11.22 ] ~ [ linux-5.10.228 ] ~ [ linux-5.9.16 ] ~ [ linux-5.8.18 ] ~ [ linux-5.7.19 ] ~ [ linux-5.6.19 ] ~ [ linux-5.5.19 ] ~ [ linux-5.4.284 ] ~ [ linux-5.3.18 ] ~ [ linux-5.2.21 ] ~ [ linux-5.1.21 ] ~ [ linux-5.0.21 ] ~ [ linux-4.20.17 ] ~ [ linux-4.19.322 ] ~ [ linux-4.18.20 ] ~ [ linux-4.17.19 ] ~ [ linux-4.16.18 ] ~ [ linux-4.15.18 ] ~ [ linux-4.14.336 ] ~ [ linux-4.13.16 ] ~ [ linux-4.12.14 ] ~ [ linux-4.11.12 ] ~ [ linux-4.10.17 ] ~ [ linux-4.9.337 ] ~ [ linux-4.4.302 ] ~ [ linux-3.10.108 ] ~ [ linux-2.6.32.71 ] ~ [ linux-2.6.0 ] ~ [ linux-2.4.37.11 ] ~ [ unix-v6-master ] ~ [ ccs-tools-1.8.9 ] ~ [ policy-sample ] ~
Architecture: ~ [ i386 ] ~ [ alpha ] ~ [ m68k ] ~ [ mips ] ~ [ ppc ] ~ [ sparc ] ~ [ sparc64 ] ~

  1 Kernel driver ds620
  2 ===================
  3 
  4 Supported chips:
  5 
  6   * Dallas Semiconductor DS620
  7 
  8     Prefix: 'ds620'
  9 
 10     Datasheet: Publicly available at the Dallas Semiconductor website
 11 
 12                http://www.dalsemi.com/
 13 
 14 Authors:
 15         Roland Stigge <stigge@antcom.de>
 16         based on ds1621.c by
 17         Christian W. Zuckschwerdt <zany@triq.net>
 18 
 19 Description
 20 -----------
 21 
 22 The DS620 is a (one instance) digital thermometer and thermostat. It has both
 23 high and low temperature limits which can be user defined (i.e.  programmed
 24 into non-volatile on-chip registers). Temperature range is -55 degree Celsius
 25 to +125. Between 0 and 70 degree Celsius, accuracy is 0.5 Kelvin. The value
 26 returned via sysfs displays post decimal positions.
 27 
 28 The thermostat function works as follows: When configured via platform_data
 29 (struct ds620_platform_data) .pomode == 0 (default), the thermostat output pin
 30 PO is always low. If .pomode == 1, the thermostat is in PO_LOW mode. I.e., the
 31 output pin PO becomes active when the temperature falls below temp1_min and
 32 stays active until the temperature goes above temp1_max.
 33 
 34 Likewise, with .pomode == 2, the thermostat is in PO_HIGH mode. I.e., the PO
 35 output pin becomes active when the temperature goes above temp1_max and stays
 36 active until the temperature falls below temp1_min.
 37 
 38 The PO output pin of the DS620 operates active-low.

~ [ source navigation ] ~ [ diff markup ] ~ [ identifier search ] ~

kernel.org | git.kernel.org | LWN.net | Project Home | SVN repository | Mail admin

Linux® is a registered trademark of Linus Torvalds in the United States and other countries.
TOMOYO® is a registered trademark of NTT DATA CORPORATION.

sflogo.php