Version: ~ [ linux-6.11.5 ] ~ [ linux-6.10.14 ] ~ [ linux-6.9.12 ] ~ [ linux-6.8.12 ] ~ [ linux-6.7.12 ] ~ [ linux-6.6.58 ] ~ [ linux-6.5.13 ] ~ [ linux-6.4.16 ] ~ [ linux-6.3.13 ] ~ [ linux-6.2.16 ] ~ [ linux-6.1.114 ] ~ [ linux-6.0.19 ] ~ [ linux-5.19.17 ] ~ [ linux-5.18.19 ] ~ [ linux-5.17.15 ] ~ [ linux-5.16.20 ] ~ [ linux-5.15.169 ] ~ [ linux-5.14.21 ] ~ [ linux-5.13.19 ] ~ [ linux-5.12.19 ] ~ [ linux-5.11.22 ] ~ [ linux-5.10.228 ] ~ [ linux-5.9.16 ] ~ [ linux-5.8.18 ] ~ [ linux-5.7.19 ] ~ [ linux-5.6.19 ] ~ [ linux-5.5.19 ] ~ [ linux-5.4.284 ] ~ [ linux-5.3.18 ] ~ [ linux-5.2.21 ] ~ [ linux-5.1.21 ] ~ [ linux-5.0.21 ] ~ [ linux-4.20.17 ] ~ [ linux-4.19.322 ] ~ [ linux-4.18.20 ] ~ [ linux-4.17.19 ] ~ [ linux-4.16.18 ] ~ [ linux-4.15.18 ] ~ [ linux-4.14.336 ] ~ [ linux-4.13.16 ] ~ [ linux-4.12.14 ] ~ [ linux-4.11.12 ] ~ [ linux-4.10.17 ] ~ [ linux-4.9.337 ] ~ [ linux-4.4.302 ] ~ [ linux-3.10.108 ] ~ [ linux-2.6.32.71 ] ~ [ linux-2.6.0 ] ~ [ linux-2.4.37.11 ] ~ [ unix-v6-master ] ~ [ ccs-tools-1.8.9 ] ~ [ policy-sample ] ~
Architecture: ~ [ i386 ] ~ [ alpha ] ~ [ m68k ] ~ [ mips ] ~ [ ppc ] ~ [ sparc ] ~ [ sparc64 ] ~

  1 Kernel driver sht21
  2 ===================
  3 
  4 Supported chips:
  5 
  6   * Sensirion SHT21
  7 
  8     Prefix: 'sht21'
  9 
 10     Addresses scanned: none
 11 
 12     Datasheet: Publicly available at the Sensirion website
 13 
 14     https://www.sensirion.com/file/datasheet_sht21
 15 
 16 
 17 
 18   * Sensirion SHT25
 19 
 20     Prefix: 'sht25'
 21 
 22     Addresses scanned: none
 23 
 24     Datasheet: Publicly available at the Sensirion website
 25 
 26     https://www.sensirion.com/file/datasheet_sht25
 27 
 28 
 29 
 30 Author:
 31 
 32   Urs Fleisch <urs.fleisch@sensirion.com>
 33 
 34 Description
 35 -----------
 36 
 37 The SHT21 and SHT25 are humidity and temperature sensors in a DFN package of
 38 only 3 x 3 mm footprint and 1.1 mm height. The difference between the two
 39 devices is the higher level of precision of the SHT25 (1.8% relative humidity,
 40 0.2 degree Celsius) compared with the SHT21 (2.0% relative humidity,
 41 0.3 degree Celsius).
 42 
 43 The devices communicate with the I2C protocol. All sensors are set to the same
 44 I2C address 0x40, so an entry with I2C_BOARD_INFO("sht21", 0x40) can be used
 45 in the board setup code.
 46 
 47 sysfs-Interface
 48 ---------------
 49 
 50 temp1_input
 51         - temperature input
 52 
 53 humidity1_input
 54         - humidity input
 55 eic
 56         - Electronic Identification Code
 57 
 58 Notes
 59 -----
 60 
 61 The driver uses the default resolution settings of 12 bit for humidity and 14
 62 bit for temperature, which results in typical measurement times of 22 ms for
 63 humidity and 66 ms for temperature. To keep self heating below 0.1 degree
 64 Celsius, the device should not be active for more than 10% of the time,
 65 e.g. maximum two measurements per second at the given resolution.
 66 
 67 Different resolutions, the on-chip heater, and using the CRC checksum
 68 are not supported yet.

~ [ source navigation ] ~ [ diff markup ] ~ [ identifier search ] ~

kernel.org | git.kernel.org | LWN.net | Project Home | SVN repository | Mail admin

Linux® is a registered trademark of Linus Torvalds in the United States and other countries.
TOMOYO® is a registered trademark of NTT DATA CORPORATION.

sflogo.php